mirror of
https://github.com/grafana/grafana.git
synced 2025-02-25 18:55:37 -06:00
Alerting: Make Unified Alerting enabled by default for those who do not use legacy alerting (#42200)
* update AlertingEnabled and UnifiedAlertingSettings.Enabled to be pointers * add a pseudo migration to fix the AlertingEnabled and UnifiedAlertingSettings.Enabled if the latter is not defined * update the default configuration file to make default value for both 'enabled' flags be undefined Misc * update Migrator to expose DB engine. This is needed for a ualert migration to access the database while the list of migrations is created. * add more verbose failure when migrations do not match Co-authored-by: gotjosh <josue@grafana.com> Co-authored-by: Yuriy Tseretyan <yuriy.tseretyan@grafana.com> Co-authored-by: gillesdemey <gilles.de.mey@gmail.com>
This commit is contained in:
@@ -7,6 +7,7 @@ import (
|
||||
"time"
|
||||
|
||||
"github.com/grafana/grafana-plugin-sdk-go/backend/gtime"
|
||||
|
||||
"github.com/grafana/grafana/pkg/util"
|
||||
|
||||
"github.com/prometheus/alertmanager/cluster"
|
||||
@@ -63,26 +64,60 @@ type UnifiedAlertingSettings struct {
|
||||
EvaluationTimeout time.Duration
|
||||
ExecuteAlerts bool
|
||||
DefaultConfiguration string
|
||||
Enabled bool
|
||||
Enabled *bool // determines whether unified alerting is enabled. If it is nil then user did not define it and therefore its value will be determined during migration. Services should not use it directly.
|
||||
DisabledOrgs map[int64]struct{}
|
||||
}
|
||||
|
||||
// IsEnabled returns true if UnifiedAlertingSettings.Enabled is either nil or true.
|
||||
// It hides the implementation details of the Enabled and simplifies its usage.
|
||||
func (u *UnifiedAlertingSettings) IsEnabled() bool {
|
||||
return u.Enabled == nil || *u.Enabled
|
||||
}
|
||||
|
||||
func (cfg *Cfg) readUnifiedAlertingEnabledSetting(section *ini.Section) (*bool, error) {
|
||||
enabled, err := section.Key("enabled").Bool()
|
||||
// the unified alerting is not enabled by default. First, check the feature flag
|
||||
if err != nil {
|
||||
// TODO: Remove in Grafana v9
|
||||
if cfg.FeatureToggles["ngalert"] {
|
||||
cfg.Logger.Warn("ngalert feature flag is deprecated: use unified alerting enabled setting instead")
|
||||
enabled = true
|
||||
// feature flag overrides the legacy alerting setting.
|
||||
legacyAlerting := false
|
||||
AlertingEnabled = &legacyAlerting
|
||||
return &enabled, nil
|
||||
}
|
||||
// next, check whether legacy flag is set
|
||||
if AlertingEnabled != nil && !*AlertingEnabled {
|
||||
enabled = true
|
||||
return &enabled, nil // if legacy alerting is explicitly disabled, enable the unified alerting by default.
|
||||
}
|
||||
// NOTE: If the enabled flag is still not defined, the final decision is made during migration (see sqlstore.migrations.ualert.CheckUnifiedAlertingEnabledByDefault).
|
||||
cfg.Logger.Info("The state of unified alerting is still not defined. The decision will be made during as we run the database migrations")
|
||||
return nil, nil // the flag is not defined
|
||||
}
|
||||
|
||||
// If unified alerting is defined explicitly as well as legacy alerting and both are enabled, return error.
|
||||
if enabled && AlertingEnabled != nil && *AlertingEnabled {
|
||||
return nil, errors.New("both legacy and Grafana 8 Alerts are enabled. Disable one of them and restart")
|
||||
}
|
||||
// if legacy alerting is not defined but unified is determined then update the legacy with inverted value
|
||||
if AlertingEnabled == nil {
|
||||
legacyEnabled := !enabled
|
||||
AlertingEnabled = &legacyEnabled
|
||||
}
|
||||
return &enabled, nil
|
||||
}
|
||||
|
||||
// ReadUnifiedAlertingSettings reads both the `unified_alerting` and `alerting` sections of the configuration while preferring configuration the `alerting` section.
|
||||
// It first reads the `unified_alerting` section, then looks for non-defaults on the `alerting` section and prefers those.
|
||||
func (cfg *Cfg) ReadUnifiedAlertingSettings(iniFile *ini.File) error {
|
||||
var err error
|
||||
uaCfg := UnifiedAlertingSettings{}
|
||||
ua := iniFile.Section("unified_alerting")
|
||||
uaCfg.Enabled = ua.Key("enabled").MustBool(false)
|
||||
|
||||
// TODO: Deprecate this in v8.4, if the old feature toggle ngalert is set, enable Grafana 8 Unified Alerting anyway.
|
||||
if !uaCfg.Enabled && cfg.FeatureToggles["ngalert"] {
|
||||
cfg.Logger.Warn("ngalert feature flag is deprecated: use unified alerting enabled setting instead")
|
||||
uaCfg.Enabled = true
|
||||
AlertingEnabled = false
|
||||
}
|
||||
|
||||
if uaCfg.Enabled && AlertingEnabled {
|
||||
return errors.New("both legacy and Grafana 8 Alerts are enabled")
|
||||
uaCfg.Enabled, err = cfg.readUnifiedAlertingEnabledSetting(ua)
|
||||
if err != nil {
|
||||
return err
|
||||
}
|
||||
|
||||
uaCfg.DisabledOrgs = make(map[int64]struct{})
|
||||
@@ -95,7 +130,6 @@ func (cfg *Cfg) ReadUnifiedAlertingSettings(iniFile *ini.File) error {
|
||||
uaCfg.DisabledOrgs[orgID] = struct{}{}
|
||||
}
|
||||
|
||||
var err error
|
||||
uaCfg.AdminConfigPollInterval, err = gtime.ParseDuration(valueAsString(ua, "admin_config_poll_interval", (schedulerDefaultAdminConfigPollInterval).String()))
|
||||
if err != nil {
|
||||
return err
|
||||
|
||||
Reference in New Issue
Block a user