#13425 Fix ICD/AICD valve output in schedule generation
ICD valves now produce WSEGVALV and AICD valves now produce WSEGAICD in the generated schedule. Three root causes were fixed: - Create per-event valve templates with proper parameters instead of reusing default templates that lack orifice diameter and AICD fields - Use perforation interval range for ICD/AICD valve positioning so valveLocations() returns non-empty results for the accumulator - Add 5 AICD parameter fields to the Python API and event classes
This commit is contained in:
1 parent
82e2dbc434
commit
1ec53cc3f2
7 files changed
+286
-15
No files matched your search
@@ -513,14 +513,18 @@ class TestScheduleGeneration:
|
||||
"""Test that wells only appear in schedule sections at their event dates, not earlier.
|
||||
|
||||
Scenario:
|
||||
- Add tubing + perf event for well A at 2024-01-01 (depth 2000-2200)
|
||||
- Add tubing + perf event for well B at 2024-03-01 (depth 1500-1700)
|
||||
- Add another tubing + perf event for well A at 2024-04-01 (depth 1800-2000, different diameter)
|
||||
- Add tubing + perf + ICV valve for well A at 2024-01-01 (depth 2000-2200, valve at 2100)
|
||||
- Add tubing + perf + ICD valve for well B at 2024-03-01 (depth 1500-1700, valve at 1600)
|
||||
- Add tubing + perf + ICV valve + perf + AICD valve for well A at 2024-04-01
|
||||
(perf 1800-2000 with ICV at 1900, perf 2250-2400 with AICD at 2300)
|
||||
- Set timestamp to 2024-12-31 (after all events)
|
||||
- Verify well A appears in January and April sections with different COMPSEGS
|
||||
- Verify well B appears in March section but NOT in January section
|
||||
- Verify each perf event has distinct diameter and skin_factor values
|
||||
- Verify April WELSEGS has different inner_diameter than January WELSEGS
|
||||
- Verify WSEGVALV appears in all sections (ICV in Jan/Apr, ICD in Mar produces WSEGVALV)
|
||||
- Verify WSEGAICD appears only in April (AICD valve with valid params), not in Jan or Mar
|
||||
- Verify April WSEGVALV values do NOT leak into January section
|
||||
"""
|
||||
project, case, timeline = project_with_case_and_well
|
||||
|
||||
@@ -547,6 +551,15 @@ class TestScheduleGeneration:
|
||||
skin_factor=0.5,
|
||||
state="OPEN",
|
||||
)
|
||||
timeline.add_valve_event(
|
||||
event_date="2024-01-01",
|
||||
well_path=well_path_a,
|
||||
measured_depth=2100.0,
|
||||
valve_type="ICV",
|
||||
state="OPEN",
|
||||
flow_coefficient=0.7,
|
||||
area=0.0001,
|
||||
)
|
||||
|
||||
# Add tubing + perforation for well B at 2024-03-01 (depth 1500-1700)
|
||||
timeline.add_tubing_event(
|
||||
@@ -566,6 +579,15 @@ class TestScheduleGeneration:
|
||||
skin_factor=0.8,
|
||||
state="OPEN",
|
||||
)
|
||||
timeline.add_valve_event(
|
||||
event_date="2024-03-01",
|
||||
well_path=well_path_b,
|
||||
measured_depth=1600.0,
|
||||
valve_type="ICD",
|
||||
state="OPEN",
|
||||
flow_coefficient=0.6,
|
||||
area=0.00012,
|
||||
)
|
||||
|
||||
# Add another tubing + perforation for well A at 2024-04-01 at a different depth (1800-2000)
|
||||
timeline.add_tubing_event(
|
||||
@@ -585,6 +607,38 @@ class TestScheduleGeneration:
|
||||
skin_factor=0.3,
|
||||
state="OPEN",
|
||||
)
|
||||
timeline.add_valve_event(
|
||||
event_date="2024-04-01",
|
||||
well_path=well_path_a,
|
||||
measured_depth=1900.0,
|
||||
valve_type="ICV",
|
||||
state="OPEN",
|
||||
flow_coefficient=0.5,
|
||||
area=0.0002,
|
||||
)
|
||||
timeline.add_perf_event(
|
||||
event_date="2024-04-01",
|
||||
well_path=well_path_a,
|
||||
start_md=2250.0,
|
||||
end_md=2400.0,
|
||||
diameter=0.12,
|
||||
skin_factor=0.4,
|
||||
state="OPEN",
|
||||
)
|
||||
timeline.add_valve_event(
|
||||
event_date="2024-04-01",
|
||||
well_path=well_path_a,
|
||||
measured_depth=2300.0,
|
||||
valve_type="AICD",
|
||||
state="OPEN",
|
||||
flow_coefficient=0.6,
|
||||
area=0.00015,
|
||||
aicd_strength=0.00021,
|
||||
aicd_density_calib_fluid=1000.0,
|
||||
aicd_viscosity_calib_fluid=1.0,
|
||||
aicd_vol_flow_exp=2.1,
|
||||
aicd_visc_func_exp=0.5,
|
||||
)
|
||||
|
||||
# Set timestamp to 2024-12-31 (after all events)
|
||||
timeline.set_timestamp(timestamp="2024-12-31")
|
||||
@@ -686,14 +740,15 @@ class TestScheduleGeneration:
|
||||
"(January has perfs at 2000-2200, April adds perfs at 1800-2000)"
|
||||
)
|
||||
|
||||
# Verify January COMPSEGS contains the 2000-2200 range
|
||||
assert "2000" in january_compsegs and "2200" in january_compsegs, (
|
||||
"January COMPSEGS should contain perforation range 2000-2200"
|
||||
# Verify January COMPSEGS contains the ICV valve depth 2100
|
||||
# (ICV redirects perforation intersections to the valve measured depth)
|
||||
assert "2100" in january_compsegs, (
|
||||
"January COMPSEGS should contain ICV valve depth 2100"
|
||||
)
|
||||
|
||||
# Verify April COMPSEGS contains the 1800-2000 range
|
||||
assert "1800" in april_compsegs and "2000" in april_compsegs, (
|
||||
"April COMPSEGS should contain perforation range 1800-2000"
|
||||
# Verify April COMPSEGS contains the ICV valve depth 1900
|
||||
assert "1900" in april_compsegs, (
|
||||
"April COMPSEGS should contain ICV valve depth 1900"
|
||||
)
|
||||
|
||||
# Verify WELSEGS sections exist for tubing events
|
||||
@@ -736,6 +791,63 @@ class TestScheduleGeneration:
|
||||
"April COMPDAT should contain skin_factor 0.3 from third perf event"
|
||||
)
|
||||
|
||||
# Verify WSEGVALV appears in January section (valve event at 2024-01-01)
|
||||
assert "WSEGVALV" in january_section, (
|
||||
"January section should contain WSEGVALV for well A (valve event at 2024-01-01)"
|
||||
)
|
||||
|
||||
# Verify WSEGVALV appears in March section (ICD valve produces WSEGVALV)
|
||||
assert "WSEGVALV" in march_section, (
|
||||
"March section should contain WSEGVALV for ICD valve"
|
||||
)
|
||||
|
||||
# Verify WSEGVALV appears in April section (valve event at 2024-04-01)
|
||||
assert "WSEGVALV" in april_section, (
|
||||
"April section should contain WSEGVALV for well A (valve event at 2024-04-01)"
|
||||
)
|
||||
|
||||
# Verify WSEGAICD appears only in April (AICD valve), not in Jan or Mar
|
||||
assert "WSEGAICD" not in january_section, (
|
||||
"January section should NOT contain WSEGAICD (no AICD valve at January)"
|
||||
)
|
||||
assert "WSEGAICD" not in march_section, (
|
||||
"March section should NOT contain WSEGAICD (well B has no AICD valve)"
|
||||
)
|
||||
assert "WSEGAICD" in april_section, (
|
||||
"April section should contain WSEGAICD for AICD valve"
|
||||
)
|
||||
|
||||
# Verify date scoping: January should have fewer WSEGVALV entries than April.
|
||||
# January: only the Jan valve is active (1 entry).
|
||||
# April: both Jan and Apr valves are active (2 entries, valves are cumulative).
|
||||
# Extract WSEGVALV blocks and count well name entries.
|
||||
jan_wsegvalv_start = january_section.find("WSEGVALV")
|
||||
jan_wsegvalv_end = january_section.find("/\n/\n", jan_wsegvalv_start)
|
||||
jan_wsegvalv = (
|
||||
january_section[jan_wsegvalv_start:jan_wsegvalv_end]
|
||||
if jan_wsegvalv_start != -1 and jan_wsegvalv_end != -1
|
||||
else ""
|
||||
)
|
||||
|
||||
apr_wsegvalv_start = april_section.find("WSEGVALV")
|
||||
apr_wsegvalv_end = april_section.find("/\n/\n", apr_wsegvalv_start)
|
||||
apr_wsegvalv = (
|
||||
april_section[apr_wsegvalv_start:apr_wsegvalv_end]
|
||||
if apr_wsegvalv_start != -1 and apr_wsegvalv_end != -1
|
||||
else ""
|
||||
)
|
||||
|
||||
jan_valve_count = jan_wsegvalv.count(well_a_name)
|
||||
apr_valve_count = apr_wsegvalv.count(well_a_name)
|
||||
|
||||
assert jan_valve_count == 1, (
|
||||
f"January WSEGVALV should have exactly 1 entry (only Jan valve active), got {jan_valve_count}"
|
||||
)
|
||||
assert apr_valve_count == 2, (
|
||||
f"April WSEGVALV should have 2 entries (both valves active), got {apr_valve_count}. "
|
||||
"The April valve should not leak into earlier sections."
|
||||
)
|
||||
|
||||
print("\n✓ Verified: Well A appears in January section (event at 2000-2200)")
|
||||
print("✓ Verified: Well B does NOT appear in January section")
|
||||
print("✓ Verified: Well B appears in March section (its event date)")
|
||||
@@ -746,6 +858,14 @@ class TestScheduleGeneration:
|
||||
)
|
||||
print("✓ Verified: April tubing values do NOT leak into January section")
|
||||
print("✓ Verified: Distinct perf diameters/skin values in COMPDAT sections")
|
||||
print("✓ Verified: WSEGVALV present in January section (ICV, 1 valve entry)")
|
||||
print("✓ Verified: WSEGVALV present in March section (ICD valve)")
|
||||
print(
|
||||
"✓ Verified: WSEGVALV present in April section (ICV, 2 valve entries, cumulative)"
|
||||
)
|
||||
print("✓ Verified: WSEGAICD present in April section (AICD valve)")
|
||||
print("✓ Verified: WSEGAICD NOT present in January or March sections")
|
||||
print("✓ Verified: April valve does NOT leak into January (date scoping)")
|
||||
|
||||
def test_example_workflow_schedule_generation(self, project_with_case_and_well):
|
||||
"""Test the exact workflow from well_event_schedule.py example.
|
||||
|
||||
Reference in new issue