Commit Graph

67 Commits

Author SHA1 Message Date
Magne Sjaastad
57cab2457e clang-format : Set PenaltyBreakAssignment to 130 2019-11-04 15:08:09 +01:00
Magne Sjaastad
7c8cf60dba clang-format : Set AllowAllParametersOfDeclarationOnNextLine to false 2019-11-04 14:35:41 +01:00
Magne Sjaastad
67e7bb0cf3 Fixes detected by cppcheck (#4974)
* Janitor : Remove obsolete pointer to dialog

* Janitor : Remove unused functions

* Janitor : Remove unused functions

* Janitor : Add explicit to constructors

* Janitor : Remove unused variables

* Janitor : Remove unused functions related to summary plot templates

* clang-tidy : Use nullptr instead of 0

* clang-tidy : Fix usage of virtual and override

* Upped to version 2019.08.2-dev.05

* Janitor : Remove unused variables

* Janitor : Clean up several cppcheck issues

* Janitor : Add cppcheck config files

* Janitor : Use const when possible
2019-11-03 08:37:03 +01:00
Magne Sjaastad
f41edcee44 #4751 System : Use std::wstring to communicate file path 2019-09-23 13:37:29 +02:00
Magne Sjaastad
fe9e567825 #4683 clang-format on all files in ApplicationCode 2019-09-06 10:57:22 +02:00
Magne Sjaastad
79df075fe4 #4136 Export of Flow Characteristics : Rename 2019-06-23 15:12:33 +02:00
Magne Sjaastad
7c054c47f2 #4495 Active Cells : Handle active cells for dual porosity models based on PORV 2019-06-20 15:08:20 +02:00
Magne Sjaastad
c1b9738298 #4434 Flow Diag adjustments : Use ecl_grid_free 2019-06-18 12:27:29 +02:00
Magne Sjaastad
ff16156c2a #4434 Flow Diag adjustments : Use active cells from PORV in Flow Diag 2019-06-18 10:58:07 +02:00
Jacob Støren
e21a0da543 #3958 Refactoring: Remove resultIndex in maxTimeStepResult 2019-01-25 16:19:13 +01:00
Jacob Støren
ccfee8f34a #3958 Starting refactoring of eclipse results addressing
Preparations for time diff results
2019-01-25 16:19:13 +01:00
Bård Skaflestad
dc8931f782 Update Flow Diagnostics Application Library
Fixes incorrect horizontal and vertical end-point scaling of model's
saturation functions.

API Change: No longer supports user-selected behaviour for treating
scaled end-points with a sentinel value (-1.0E+20).  That option was
introduced due to incomplete understanding of the semantics of the
sentinel value.  Now that we understand the meaning (use actual,
unscaled end-point value from input table), we no longer need the
option.  Update the calling code in RigFlowDiagSolverInterface.cpp
accordingly.
2018-10-25 13:40:08 +02:00
Magne Sjaastad
f61b82dd35 System : System : Introduce compiler warning 4456 with fixes 2018-09-25 07:37:40 +02:00
Magne Sjaastad
9e3a100bcc #3253 OpenMP : Give name to all critical sections 2018-08-27 13:04:29 +02:00
Magne Sjaastad
fe07b60392 CppCheck : Several fixes
Add missing initializers
Guard potential null pointer access
2018-08-02 19:22:03 +02:00
Bjørn Erik Jensen
e4aa7d681d #2852 OPM. Updated flow diag solver interface after OPM upgrade 2018-05-07 14:43:24 +02:00
Magne Sjaastad
7ce6177bc5 System : Add missing braces 2018-02-23 22:39:29 +01:00
Rebecca Cox
f598e6905c #2419 Do not make OpmFlowDiagStat if result is fracture (DUAL) 2018-01-29 14:41:07 +01:00
Jacob Støren
5855e412e7 #2375 Fix missing catch of exeptions from pvt/relperm curve generation 2018-01-19 15:21:17 +01:00
Jacob Støren
6adcbd9c56 #2375 Fix missing catch of exceptions from opm-flowdiagnostics libraries 2018-01-19 12:46:53 +01:00
sigurdp
434d03b9d7 #2318 Added workaround that guards initialization of relative permeability evaluation library since opening of special EGRID file causes exception in library and crash 2018-01-05 11:00:40 +01:00
Jacob Støren
3f22c096d8 #2294 Use phase saturation corrected PORV when calculating TOF for a single phase 2018-01-02 14:45:42 +01:00
sigurdp
f716dacb24 Pvt Plot: Display Rs/Rv values of curve's sample points in tool tip, #2255 2017-12-13 14:56:10 +01:00
sigurdp
01ae19ebbc #2235 RelPerm/PVT Plot: Added unit labels to relevant axes 2017-12-11 16:12:31 +01:00
sigurdp
07b1bbca4b RelPerm Plot: Try and enable handling of invalid scaled saturation end-points by ignoring these, but currently does not seem to give the expected results. 2017-12-11 13:07:35 +01:00
sigurdp
56febb9e92 #2192 RelPerm Plot: Utilize new functionality in opm-flowdiagnostics-applications to show the pressure in case-units 2017-12-11 13:07:35 +01:00
sigurdp
09c09a7386 Upgraded opm-flowdiagnostics-applications to a773bcfc963705679ecc28f58048fc38936fbbc6 2017-12-11 11:15:09 +01:00
sigurdp
a285ae8f61 PVT Plot: Added guarding to prevent access visolations when querying dynamic properties for PVT plots in cases where initialization of PVT curve collection fails. 2017-12-05 16:16:58 +01:00
sigurdp
e12a931940 Added calculation of PVT related dynamic properties and display of these in the PVT FVF and Viscosity plots as a point marker. Started using flow diagnostics library's output unit conversion for PVT curves to align output units with the case units. #1990 2017-12-05 14:18:46 +01:00
sigurdp
9e3868d6d8 First attempt at using unit conversion when getting PVT curve data (commented out due to crash) 2017-12-05 10:43:44 +01:00
sigurdp
85832ae0bc PVT Plot: Added warning message if PVT plotting could not be initialized 2017-11-30 11:28:07 +01:00
sigurdp
3b1775ad4d #1994 PVT Plot: Removed water phase from plot, started implementing display of pressure marker, but this is not yet active. 2017-11-28 09:15:11 +01:00
sigurdp
aa1bbbe2d9 #1994 First cut implementing PVT plots 2017-11-28 09:15:11 +01:00
sigurdp
65fe3ba902 #2063 Added support for showing RelPerm plot curves without end-point scaling 2017-11-24 08:36:44 +01:00
sigurdp
14c1b5a595 Enabled caclulation and plotting of PCOG and PCOW now that opm-flowdiagnostics-applications have been updated 2017-11-24 08:36:44 +01:00
sigurdp
5f5abdf347 Working on adding SWAT and SGAS markers to RelPerm plot, #2061 2017-11-24 08:36:44 +01:00
Bjørn Erik Jensen
71caab54ec Added first cut extraction and plotting of RelPerm plots. Also added skeleton implementation of extraction and plotting of PVT plots. #1991, #1992, #1992, #2014 2017-10-27 10:20:34 +02:00
Jacob Støren
4d097a3149 #1988 Update flow diag libraries to handle multiple connections in same well, and have PVT Rel Perm support. 2017-10-11 18:05:53 +02:00
Bjørnar Grip Fjær
65ce0d3788 #1377 Flow Characteristics Plot: Calculate for a defined set of cells 2017-08-17 11:25:13 +02:00
Magne Sjaastad
89684c243f #1755 Use namespace RiaDefines instead of class 2017-08-11 14:28:42 +02:00
Magne Sjaastad
c4aa625d33 #1755 Move porosity model enum to separate file 2017-08-11 14:27:56 +02:00
Magne Sjaastad
88bbea6339 #1755 Remove porosity enum from RifReaderInterface 2017-08-11 14:27:22 +02:00
Bjørnar Grip Fjær
efb79ac753 #1202 Flow: Handle separate phase solutions 2017-08-10 15:08:30 +02:00
Bjørnar Grip Fjær
747721a7f8 #1698 Use opm-flowdiagnostics calculation of fluxes if not present in Eclipse restart file 2017-08-10 10:09:24 +02:00
Bjørnar Grip Fjær
7598d8c196 #1696 Threshold option for aquifer cells 2017-08-09 14:10:39 +02:00
Jacob Støren
f9a29925c5 #1483 Flow Characteristics plot: Set pore volume fraction threshold to 0.1 2017-05-29 13:16:40 +02:00
Jacob Støren
4e091641a4 #1483 Update opm-flowdiagnostics and ..-applications
to b6e59ddcd2fe, and ccaaa4dd1b55 respectively.

In order to include flowCapacityStorageCapacityCurve with max pv fraction threshold
2017-05-29 13:08:32 +02:00
Magne Sjaastad
54c6e1c600 #1372 Update solver interface due to API changes in flow diagnostics 2017-05-12 12:22:50 +02:00
Jacob Støren
1fefc6124f #1321 Wip: First shot on bringing the flow characteristics curves up into the open. 2017-03-27 18:13:38 +02:00
Jacob Støren
c39462d19a #1345 Fixed. Injector TOF results ended up with a double unit conversion, because tracers with no cells were wrongfully added to the flow diag solver solution. 2017-03-22 14:04:13 +01:00