The plotting of curve values for connections to a segment fails in some cases. The current implementation finds the segment a connection is attached to, and use the depth (both MD and TVD) information from this segment. This method is not working in all cases.
Use the reported location of connections attached to segments based on CONLENST and CONLENEN. When measured depth is requested, use these values. There might be gaps in the reported segment sequence.
Use CONDEPTH when TVD depth is requested.
Use CONBRNO to find the branch number, and then use lookup table branchIdsAndOneBasedBranchIndices to find the branch index. Use the branch index to filter the results for requested branch.
The number of values in CON* result values is different to result values for SEG* results.
The segment symbol is displayed once per segment. Previous code used segment start as symbol location. Add support for selecting the location for the segment indicator, either start, mid or end.
When reading segment property values, always use segment end as the curve is plotted using step left.
- add CONGRAT
- add pressure track
- add CONFAC
- fix some plot layout issues
- Fix bug for first segment MD location
- Add default scale factor 1e-3 for gas curves
- Avoid inf values in some curves, seen in PRESSURE and CONFAC
- Use assignment in statements instead of std::get
* Add topology curves and default plot
* Improve visual appearance
* Update sub module opm-common
* Add support for INCLUDE keyword to allow parsing of include files recursively
* Search for *.DATA with fallback to *.SCH to automatically import WESEGLINK data
* Find annulus branch based on MD diff on segment start
* Stop growing device branch if segment starts at a lower MD than previous
* Add unit test used to read data from WSEGLINK
* Add segment branch type
* Add detection of device branches
* Add data source stepping on branch type
* parse wseglink data
* add RFT case as child of RimFileSummaryCase