The plotting of curve values for connections to a segment fails in some cases. The current implementation finds the segment a connection is attached to, and use the depth (both MD and TVD) information from this segment. This method is not working in all cases.
Use the reported location of connections attached to segments based on CONLENST and CONLENEN. When measured depth is requested, use these values. There might be gaps in the reported segment sequence.
Use CONDEPTH when TVD depth is requested.
Use CONBRNO to find the branch number, and then use lookup table branchIdsAndOneBasedBranchIndices to find the branch index. Use the branch index to filter the results for requested branch.
The number of values in CON* result values is different to result values for SEG* results.
* Add unit test used to read data from WSEGLINK
* Add segment branch type
* Add detection of device branches
* Add data source stepping on branch type
* parse wseglink data
* add RFT case as child of RimFileSummaryCase
Add reader for RFT data using opm-common
Extend RFT curve with support for RFT segment data
Adjustments related to horizontal well log plots
8581 Well Log Plot : Update of curve appearance does not update plot