- support selection of multiple values for multiple producer variables
- use one color for curves in a curve set representing a VFP curve collection
- use symbols to indicate individual family values for curves
- show all required values to identify curves as curve legend text and curve mouse hover text
- make sure all available settings of axis property object is applied to the plot axis
- support display of all curve data using "Show Plot Data"
Remove resolveReferencesRecursively() and initAfterReadRecursively() from PdmDocument::readFile(). These functions will be called in RiaApplication::loadProject after the file paths modifications are done. This will ensure that file paths can be used in initAfterRead() functions.
* AppFwk: When clearing a tree selection, make sure all values are cleared
* Fix deprecated implicit lambda
* Add support for using the closest value in addition to exact match
* Add table data source object and add plot with multiple data sources
Delete the temporary RimVfpDeck class
Add RimVfpTable to represent a table in a data source
Add plot able to show data from multiple tables
* AppFwk: Make it possible to call resolveReferences multiple times
Use case: Vfp tables are stored in files. Multiple tables can be present in one file. Pdm table objects are created after resolve references is done as part of parsing file. When the Pdm object are created, resolveReferences can be called once more.
* Call resolveReferencesRecursively() after RimVfpTable objects are created
Statistics can be computed in two ways, precise using all available cell values and fast based on a histogram. A flag indicates if the P10/P90 values are calculated. Check this flag before assigning values using the fast histogram method.
Rebuild and update of the project tree for summary objects in Data Sources can be time consuming for large cases. Make sure the update of UI only happens when required.
No change in temperature is expected outside of reservoir between
first (geostatic) and other time steps when exporting reactivation model.
I.e. the temperature gradient and "top of reservoir" temperature from the
geostatic step should be used on all time steps.
Fixes#11405.