Files
ResInsight/ApplicationLibCode/ProjectDataModel/Histogram
Kristian Bendiksen 05588f4327 #14524 Histogram: Reset user-defined bin range on property change
A user-defined bin range is tied to the value range of a specific result: a
range set up for FLUXNUM does not apply to PERMX. Reset the bin range mode to
Automatic and the min/max cutoffs to their defaults when another property is
selected, and reset the stale cutoffs when the user sets the bin range mode
back to Automatic.
2026-08-19 12:23:07 +02:00
..