Kristian Bendiksen 1ec53cc3f2 #13425 Fix ICD/AICD valve output in schedule generation
ICD valves now produce WSEGVALV and AICD valves now produce WSEGAICD
in the generated schedule. Three root causes were fixed:

- Create per-event valve templates with proper parameters instead of
  reusing default templates that lack orifice diameter and AICD fields
- Use perforation interval range for ICD/AICD valve positioning so
  valveLocations() returns non-empty results for the accumulator
- Add 5 AICD parameter fields to the Python API and event classes
2026-02-12 08:15:22 +01:00
..