assigning BHP limit for WCONHIST and WCONINJH keywords
This commit is contained in:
@@ -850,7 +850,7 @@ BOOST_AUTO_TEST_CASE(WCH_All_Specified_BHP_Defaulted)
|
||||
BOOST_CHECK(p.hasProductionControl(Opm::WellProducer::BHP));
|
||||
BOOST_CHECK_EQUAL(p.VFPTableNumber, 12);
|
||||
BOOST_CHECK_EQUAL(p.ALQValue, 18.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 100.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 101325.);
|
||||
}
|
||||
|
||||
BOOST_AUTO_TEST_CASE(WCH_ORAT_Defaulted_BHP_Defaulted)
|
||||
@@ -868,7 +868,7 @@ BOOST_AUTO_TEST_CASE(WCH_ORAT_Defaulted_BHP_Defaulted)
|
||||
BOOST_CHECK(p.hasProductionControl(Opm::WellProducer::BHP));
|
||||
BOOST_CHECK_EQUAL(p.VFPTableNumber, 12);
|
||||
BOOST_CHECK_EQUAL(p.ALQValue, 18.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 100.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 101325.);
|
||||
}
|
||||
|
||||
BOOST_AUTO_TEST_CASE(WCH_OWRAT_Defaulted_BHP_Defaulted)
|
||||
@@ -886,7 +886,7 @@ BOOST_AUTO_TEST_CASE(WCH_OWRAT_Defaulted_BHP_Defaulted)
|
||||
BOOST_CHECK(p.hasProductionControl(Opm::WellProducer::BHP));
|
||||
BOOST_CHECK_EQUAL(p.VFPTableNumber, 12);
|
||||
BOOST_CHECK_EQUAL(p.ALQValue, 18.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 100.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 101325.);
|
||||
}
|
||||
|
||||
BOOST_AUTO_TEST_CASE(WCH_Rates_Defaulted_BHP_Defaulted)
|
||||
@@ -904,7 +904,7 @@ BOOST_AUTO_TEST_CASE(WCH_Rates_Defaulted_BHP_Defaulted)
|
||||
BOOST_CHECK(p.hasProductionControl(Opm::WellProducer::BHP));
|
||||
BOOST_CHECK_EQUAL(p.VFPTableNumber, 12);
|
||||
BOOST_CHECK_EQUAL(p.ALQValue, 18.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 100.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 101325.);
|
||||
}
|
||||
|
||||
BOOST_AUTO_TEST_CASE(WCH_Rates_Defaulted_BHP_Specified)
|
||||
@@ -923,7 +923,7 @@ BOOST_AUTO_TEST_CASE(WCH_Rates_Defaulted_BHP_Specified)
|
||||
BOOST_CHECK_EQUAL(true, p.hasProductionControl(Opm::WellProducer::BHP));
|
||||
BOOST_CHECK_EQUAL(p.VFPTableNumber, 12);
|
||||
BOOST_CHECK_EQUAL(p.ALQValue, 18.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 100.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 101325.);
|
||||
}
|
||||
|
||||
BOOST_AUTO_TEST_CASE(WCH_Rates_NON_Defaulted_VFP)
|
||||
@@ -942,7 +942,7 @@ BOOST_AUTO_TEST_CASE(WCH_Rates_NON_Defaulted_VFP)
|
||||
BOOST_CHECK_EQUAL(true, p.hasProductionControl(Opm::WellProducer::BHP));
|
||||
BOOST_CHECK_EQUAL(p.VFPTableNumber, 3);
|
||||
BOOST_CHECK_EQUAL(p.ALQValue, 10.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 100.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 101325.);
|
||||
}
|
||||
|
||||
BOOST_AUTO_TEST_CASE(WCH_Whistctl)
|
||||
@@ -963,7 +963,7 @@ BOOST_AUTO_TEST_CASE(WCH_Whistctl)
|
||||
BOOST_CHECK_EQUAL(true, p.hasProductionControl(Opm::WellProducer::BHP));
|
||||
BOOST_CHECK_EQUAL(p.VFPTableNumber, 3);
|
||||
BOOST_CHECK_EQUAL(p.ALQValue, 10.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 100.);
|
||||
BOOST_CHECK_EQUAL(p.BHPLimit, 101325.);
|
||||
}
|
||||
|
||||
BOOST_AUTO_TEST_CASE(WCH_BHP_Specified)
|
||||
|
||||
Reference in New Issue
Block a user