Merge pull request #1351 from joakim-hove/weltarg-unit-conversio
Temporarily bypass the unit conversion in handleWELTARG
This commit is contained in:
@@ -1430,6 +1430,11 @@ namespace {
|
||||
does not check or enforce in any way that this is done (i.e. it
|
||||
is not checked or verified that the well is initialized with any
|
||||
WCONxxxx keyword).
|
||||
|
||||
Update: See the discussion following the defintions of the SI factors, due
|
||||
to a bad design we currently need the well to be specified with WCONPROD
|
||||
/ WCONHIST before WELTARG is applied, if not the units for the rates
|
||||
will be wrong.
|
||||
*/
|
||||
|
||||
void Schedule::handleWELTARG( const SCHEDULESection& section ,
|
||||
@@ -1437,9 +1442,36 @@ namespace {
|
||||
size_t currentStep,
|
||||
const ParseContext& parseContext, ErrorGuard& errors) {
|
||||
Opm::UnitSystem unitSystem = section.unitSystem();
|
||||
double siFactorL = unitSystem.parse("LiquidSurfaceVolume/Time").getSIScaling();
|
||||
double siFactorG = unitSystem.parse("GasSurfaceVolume/Time").getSIScaling();
|
||||
double siFactorP = unitSystem.parse("Pressure").getSIScaling();
|
||||
/*
|
||||
double siFactorL = unitSystem.parse("LiquidSurfaceVolume/Time").getSIScaling();
|
||||
double siFactorG = unitSystem.parse("GasSurfaceVolume/Time").getSIScaling();
|
||||
double siFactorP = unitSystem.parse("Pressure").getSIScaling();
|
||||
*/
|
||||
|
||||
/*
|
||||
Unit system handling in the UDA values has become a complete mess. The
|
||||
point is that the UDA values can *optionally* carry a dimension object
|
||||
with them, and then that unit system is transparaently used when
|
||||
calling UDAValue::get<double>(). For UDA values which come from the
|
||||
deck they are properly decorated with unitsystem, and things work as
|
||||
they should. But when it comes to *explicitly setting* UDA values from
|
||||
the API, as is done in the WELTARG implementation - things are quite
|
||||
broken.
|
||||
|
||||
What currently "works" is:
|
||||
|
||||
- The well must be fully specified with WCONPROD / WCONHIST before the
|
||||
WELTARG keyword is used.
|
||||
|
||||
- The unit conversion here in handleWELTARG is bypassed by setting the
|
||||
conversion factors to 1.0, and the conversion which comes from the
|
||||
dim objects internalized in the UDA objects will handle things on
|
||||
return.
|
||||
*/
|
||||
|
||||
const double siFactorL = 1.0;
|
||||
const double siFactorG = 1.0;
|
||||
const double siFactorP = 1.0;
|
||||
|
||||
for( const auto& record : keyword ) {
|
||||
|
||||
|
||||