Summary function glir should sum over all argument wells
This commit is contained in:
parent
58e859fb11
commit
908eebb7ed
@ -469,21 +469,21 @@ double efac( const std::vector<std::pair<std::string,double>>& eff_factors, cons
|
||||
return (it != eff_factors.end()) ? it->second : 1;
|
||||
}
|
||||
|
||||
/*
|
||||
This is bit dangerous, exactly how the ALQ value should be interpreted varies
|
||||
between the different VFP tables. The code here assumes - without checking -
|
||||
that it represents gas lift rate.
|
||||
*/
|
||||
inline quantity glir( const fn_args& args ) {
|
||||
const quantity zero = { 0.0, measure::gas_surface_rate };
|
||||
double alq_rate = 0;
|
||||
|
||||
if (args.schedule_wells.empty())
|
||||
return zero;
|
||||
for (const auto& well : args.schedule_wells) {
|
||||
auto xwPos = args.wells.find(well.name());
|
||||
if (xwPos != args.wells.end())
|
||||
alq_rate += xwPos->second.rates.get(rt::alq, 0.0);
|
||||
}
|
||||
|
||||
const auto& well = args.schedule_wells.front();
|
||||
auto xwPos = args.wells.find(well.name());
|
||||
if (xwPos == args.wells.end())
|
||||
return zero;
|
||||
|
||||
// This is bit dangerous, exactly how the ALQ value should be interpreted
|
||||
// varies between the different VFP tables. The code here assumes - without
|
||||
// checking - that it represents gas lift rate.
|
||||
return { xwPos->second.rates.get(rt::alq, 0.0), measure::gas_surface_rate };
|
||||
return { alq_rate, measure::gas_surface_rate };
|
||||
}
|
||||
|
||||
template< rt phase, bool injection = true >
|
||||
|