Test Data: Add WELLDIMS for Restart Purposes
The new restart code depends on having WELLDIMS available in order to allocate appropriately sized output vectors.
This commit is contained in:
parent
41d0a56967
commit
9637109ca8
@ -9,6 +9,15 @@ UNIFIN
|
|||||||
DIMENS
|
DIMENS
|
||||||
10 10 10 /
|
10 10 10 /
|
||||||
|
|
||||||
|
WELLDIMS
|
||||||
|
-- Item 1: NWMAX (Maximum number of wells in model)
|
||||||
|
-- Item 2: NCWMAX (Maximum number of connections per well)
|
||||||
|
-- Item 3: NGMAX (Maximum number of groups in model--excluding FIELD)
|
||||||
|
-- Item 4: NWGMAX (Maximum number of wells or child groups per group)
|
||||||
|
-- NWMAX NCWMAX NGMAX NWGMAX
|
||||||
|
6 3 1 6
|
||||||
|
/
|
||||||
|
|
||||||
GRID
|
GRID
|
||||||
DXV
|
DXV
|
||||||
10*0.25 /
|
10*0.25 /
|
||||||
|
@ -12,6 +12,15 @@ DIMENS
|
|||||||
REGDIMS
|
REGDIMS
|
||||||
10 /
|
10 /
|
||||||
|
|
||||||
|
WELLDIMS
|
||||||
|
-- Item 1: NWMAX (Maximum number of wells in model)
|
||||||
|
-- Item 2: NCWMAX (Maximum number of connections per well)
|
||||||
|
-- Item 3: NGMAX (Maximum number of groups in model--excluding FIELD)
|
||||||
|
-- Item 4: NWGMAX (Maximum number of wells or child groups per group)
|
||||||
|
-- NWMAX NCWMAX NGMAX NWGMAX
|
||||||
|
3 2 5 2
|
||||||
|
/
|
||||||
|
|
||||||
OIL
|
OIL
|
||||||
GAS
|
GAS
|
||||||
WATER
|
WATER
|
||||||
|
@ -17,6 +17,15 @@ DIMENS
|
|||||||
REGDIMS
|
REGDIMS
|
||||||
10 /
|
10 /
|
||||||
|
|
||||||
|
WELLDIMS
|
||||||
|
-- Item 1: NWMAX (Maximum number of wells in model)
|
||||||
|
-- Item 2: NCWMAX (Maximum number of connections per well)
|
||||||
|
-- Item 3: NGMAX (Maximum number of groups in model--excluding FIELD)
|
||||||
|
-- Item 4: NWGMAX (Maximum number of wells or child groups per group)
|
||||||
|
-- NWMAX NCWMAX NGMAX NWGMAX
|
||||||
|
5 2 3 2
|
||||||
|
/
|
||||||
|
|
||||||
OIL
|
OIL
|
||||||
GAS
|
GAS
|
||||||
WATER
|
WATER
|
||||||
|
@ -21,6 +21,15 @@ OIL
|
|||||||
GAS
|
GAS
|
||||||
WATER
|
WATER
|
||||||
|
|
||||||
|
WELLDIMS
|
||||||
|
-- Item 1: NWMAX (Maximum number of wells in model)
|
||||||
|
-- Item 2: NCWMAX (Maximum number of connections per well)
|
||||||
|
-- Item 3: NGMAX (Maximum number of groups in model--excluding FIELD)
|
||||||
|
-- Item 4: NWGMAX (Maximum number of wells or child groups per group)
|
||||||
|
-- NWMAX NCWMAX NGMAX NWGMAX
|
||||||
|
4 2 3 2
|
||||||
|
/
|
||||||
|
|
||||||
GRID
|
GRID
|
||||||
|
|
||||||
DX
|
DX
|
||||||
|
@ -17,6 +17,15 @@ METRIC
|
|||||||
DIMENS
|
DIMENS
|
||||||
10 10 10 /
|
10 10 10 /
|
||||||
|
|
||||||
|
WELLDIMS
|
||||||
|
-- Item 1: NWMAX (Maximum number of wells in model)
|
||||||
|
-- Item 2: NCWMAX (Maximum number of connections per well)
|
||||||
|
-- Item 3: NGMAX (Maximum number of groups in model--excluding FIELD)
|
||||||
|
-- Item 4: NWGMAX (Maximum number of wells or child groups per group)
|
||||||
|
-- NWMAX NCWMAX NGMAX NWGMAX
|
||||||
|
9 10 2 6
|
||||||
|
/
|
||||||
|
|
||||||
GRID
|
GRID
|
||||||
DXV
|
DXV
|
||||||
10*10 /
|
10*10 /
|
||||||
|