Output WGLIR=0 Unless ALQ=GRAT
This reduces the risk of users misinterpreting the curves since the unit of measure when plotting the vector will unconditionally be surface volume rate for gas. We will revisit this decision if we gain the ability to capture the actual lift gas injection rate independent of ALQ type. Suggested by: [at]tskille
This commit is contained in:
parent
2ad81c9364
commit
b638ba0f0e
@ -576,15 +576,6 @@ alq_type(const Opm::ScheduleState& sched_state,
|
||||
return sched_state.vfpprod(pc.vfp_table_number).getALQType();
|
||||
}
|
||||
|
||||
inline bool is_glir_permissible(const Opm::VFPProdTable::ALQ_TYPE alqType)
|
||||
{
|
||||
using ALQ_TYPE = Opm::VFPProdTable::ALQ_TYPE;
|
||||
|
||||
return (alqType == ALQ_TYPE::ALQ_GRAT)
|
||||
|| (alqType == ALQ_TYPE::ALQ_IGLR)
|
||||
|| (alqType == ALQ_TYPE::ALQ_TGLR);
|
||||
}
|
||||
|
||||
inline quantity glir( const fn_args& args ) {
|
||||
if (args.schedule_wells.empty()) {
|
||||
return { 0.0, measure::gas_surface_rate };
|
||||
@ -592,14 +583,6 @@ inline quantity glir( const fn_args& args ) {
|
||||
|
||||
const auto& sched_state = args.schedule[args.sim_step];
|
||||
|
||||
auto alqType = std::optional<Opm::VFPProdTable::ALQ_TYPE>{};
|
||||
|
||||
if (args.schedule_wells.size() > std::vector<Opm::Well*>::size_type{1}) {
|
||||
// Summing to group and field levels is only possible if the ALQ
|
||||
// type is gas flow rate.
|
||||
alqType = Opm::VFPProdTable::ALQ_TYPE::ALQ_GRAT;
|
||||
}
|
||||
|
||||
double alq_rate = 0.0;
|
||||
for (const auto* well : args.schedule_wells) {
|
||||
if (well->isInjector()) {
|
||||
@ -619,12 +602,7 @@ inline quantity glir( const fn_args& args ) {
|
||||
}
|
||||
|
||||
const auto thisAlqType = alq_type(sched_state, production);
|
||||
if (alqType.has_value() && (thisAlqType != alqType.value())) {
|
||||
continue;
|
||||
}
|
||||
|
||||
alqType = thisAlqType;
|
||||
if (! is_glir_permissible(thisAlqType)) {
|
||||
if (thisAlqType != Opm::VFPProdTable::ALQ_TYPE::ALQ_GRAT) {
|
||||
continue;
|
||||
}
|
||||
|
||||
@ -632,11 +610,7 @@ inline quantity glir( const fn_args& args ) {
|
||||
alq_rate += eff_fac * xwPos->second.rates.get(rt::alq, production.alq_value);
|
||||
}
|
||||
|
||||
const auto unit = !alqType.has_value() || (alqType.value() == Opm::VFPProdTable::ALQ_TYPE::ALQ_GRAT)
|
||||
? measure::gas_surface_rate
|
||||
: measure::gas_oil_ratio;
|
||||
|
||||
return { alq_rate, unit };
|
||||
return { alq_rate, measure::gas_surface_rate };
|
||||
}
|
||||
|
||||
inline quantity wwirt( const fn_args& args ) {
|
||||
|
Loading…
Reference in New Issue