Add Restart I/O Support for Well's THP
This commit adds support for saving and restoring a well's THP quantitiy. We put the THP into the summary facility's list of "required restart quantities" and pick up the value converted to output units from the SummaryState. On restart we restore the THP value to internal (SI) units and transport the value to the simulator in data::Well::thp. While here, also add the THP value to the RstWell object although currently not strictly needed in that context.
This commit is contained in:
@@ -237,6 +237,7 @@ TSTEP -- 8
|
||||
state.update("WWCT:OP_1" , 0.625);
|
||||
state.update("WGOR:OP_1" , 234.5);
|
||||
state.update("WBHP:OP_1" , 314.15);
|
||||
state.update("WTHP:OP_1" , 123.45);
|
||||
state.update("WOPTH:OP_1", 345.6);
|
||||
state.update("WWPTH:OP_1", 456.7);
|
||||
state.update("WGPTH:OP_1", 567.8);
|
||||
@@ -265,6 +266,7 @@ TSTEP -- 8
|
||||
state.update("WWCT:OP_2" , 0.0);
|
||||
state.update("WGOR:OP_2" , 0.0);
|
||||
state.update("WBHP:OP_2" , 400.6);
|
||||
state.update("WTHP:OP_2" , 234.5);
|
||||
state.update("WOPTH:OP_2", 0.0);
|
||||
state.update("WWPTH:OP_2", 0.0);
|
||||
state.update("WGPTH:OP_2", 0.0);
|
||||
@@ -293,6 +295,7 @@ TSTEP -- 8
|
||||
state.update("WWCT:OP_3" , 0.0625);
|
||||
state.update("WGOR:OP_3" , 1234.5);
|
||||
state.update("WBHP:OP_3" , 314.15);
|
||||
state.update("WTHP:OP_3" , 246.9);
|
||||
state.update("WOPTH:OP_3", 2345.6);
|
||||
state.update("WWPTH:OP_3", 3456.7);
|
||||
state.update("WGPTH:OP_3", 4567.8);
|
||||
@@ -601,6 +604,7 @@ BOOST_AUTO_TEST_CASE (Dynamic_Well_Data_Step1)
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::LiqPrRate], 1.0 + 2.0, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::VoidPrRate], 4.0, 1.0e-10);
|
||||
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::TubHeadPr], 123.45, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::FlowBHP], 314.15 , 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::WatCut] , 0.625, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::GORatio], 234.5 , 1.0e-10);
|
||||
@@ -645,6 +649,7 @@ BOOST_AUTO_TEST_CASE (Dynamic_Well_Data_Step1)
|
||||
|
||||
BOOST_CHECK_CLOSE(xwell[i1 + Ix::GasPrRate], -200.0, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i1 + Ix::VoidPrRate], -1234.0, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i1 + Ix::TubHeadPr], 234.5, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i1 + Ix::FlowBHP], 400.6, 1.0e-10);
|
||||
|
||||
BOOST_CHECK_CLOSE(xwell[i1 + Ix::WatInjTotal], 1000.0, 1.0e-10);
|
||||
@@ -736,6 +741,7 @@ BOOST_AUTO_TEST_CASE (Dynamic_Well_Data_Step2)
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::LiqPrRate], 1.0 + 2.0, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::VoidPrRate], 4.0, 1.0e-10);
|
||||
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::TubHeadPr], 123.45, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::FlowBHP], 314.15, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::WatCut] , 0.625, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i0 + Ix::GORatio], 234.5, 1.0e-10);
|
||||
@@ -781,6 +787,7 @@ BOOST_AUTO_TEST_CASE (Dynamic_Well_Data_Step2)
|
||||
BOOST_CHECK_CLOSE(xwell[i1 + Ix::LiqPrRate],
|
||||
xwell[i1 + Ix::WatPrRate], 1.0e-10);
|
||||
|
||||
BOOST_CHECK_CLOSE(xwell[i1 + Ix::TubHeadPr], 234.5, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i1 + Ix::FlowBHP], 400.6, 1.0e-10);
|
||||
|
||||
BOOST_CHECK_CLOSE(xwell[i1 + Ix::WatInjTotal], 1000.0, 1.0e-10);
|
||||
@@ -829,6 +836,7 @@ BOOST_AUTO_TEST_CASE (Dynamic_Well_Data_Step2)
|
||||
BOOST_CHECK_CLOSE(xwell[i2 + Ix::LiqPrRate], 11.0 + 12.0, 1.0e-10); // LPR
|
||||
BOOST_CHECK_CLOSE(xwell[i2 + Ix::VoidPrRate], 14.0, 1.0e-10);
|
||||
|
||||
BOOST_CHECK_CLOSE(xwell[i2 + Ix::TubHeadPr], 246.9, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i2 + Ix::FlowBHP], 314.15, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i2 + Ix::WatCut] , 0.0625, 1.0e-10);
|
||||
BOOST_CHECK_CLOSE(xwell[i2 + Ix::GORatio], 1234.5, 1.0e-10);
|
||||
|
||||
Reference in New Issue