Change polymer production output from volume -> mass Polymer injection rates are read from the simulator and not computed based on the water rate and the polymer injection concentration given in the schedule
551 lines
3.9 KiB
Plaintext
551 lines
3.9 KiB
Plaintext
-- Synthetic test deck based on Norne. This data set is meant to be a simple,
|
|
-- well-documented deck for the behaviour of SUMMARY specified output. Data
|
|
-- is mostly entered to *traceable* and does not necessarily make sense from
|
|
-- a simulation point of view.
|
|
|
|
START
|
|
10 MAI 2007 /
|
|
RUNSPEC
|
|
|
|
TITLE
|
|
SUMMARYTESTS
|
|
|
|
-- A simple 10x10x10 cube. Simple to reason about, large enough for all tests
|
|
DIMENS
|
|
10 10 10 /
|
|
|
|
REGDIMS
|
|
10 /
|
|
|
|
OIL
|
|
GAS
|
|
WATER
|
|
|
|
UNIFIN
|
|
UNIFOUT
|
|
|
|
GRID
|
|
|
|
DX
|
|
1000*1 /
|
|
DY
|
|
1000*1 /
|
|
DZ
|
|
1000*1 /
|
|
TOPS
|
|
100*1 /
|
|
|
|
-- Cell 2,1,10 is inactive
|
|
ACTNUM
|
|
901*1 0 98*1 /
|
|
|
|
PORO
|
|
1000*0.2 /
|
|
|
|
PERMX
|
|
1000*0.25/
|
|
|
|
COPY
|
|
PERMX PERMY /
|
|
PERMX PERMZ /
|
|
/
|
|
|
|
|
|
REGIONS
|
|
|
|
FIPNUM
|
|
100*1
|
|
100*2
|
|
100*3
|
|
100*4
|
|
100*5
|
|
100*6
|
|
100*7
|
|
100*8
|
|
100*9
|
|
100*10 /
|
|
|
|
|
|
SUMMARY
|
|
DATE
|
|
PERFORMA
|
|
--
|
|
-- Field Data
|
|
-- Production Rates
|
|
FVPR
|
|
FWPR
|
|
FWPRH
|
|
FOPR
|
|
FOPRH
|
|
FGPR
|
|
FGPRH
|
|
FLPR
|
|
FLPRH
|
|
FGSR
|
|
FGCR
|
|
FNPR -- solvent
|
|
FCPR
|
|
--FTPRSEA
|
|
-- Injection Rates
|
|
FVIR
|
|
FWIR
|
|
FWIRH
|
|
FGIR
|
|
FNIR -- solvent
|
|
FGIRH
|
|
-- Production Cummulatives
|
|
FVPT
|
|
FWPT
|
|
FOPT
|
|
FLPT
|
|
FLPTH
|
|
FGPT
|
|
FNPT
|
|
FOPTH
|
|
FGPTH
|
|
FWPTH
|
|
FGST
|
|
FGCT
|
|
FCPT
|
|
-- Injection Cummulatives
|
|
FVIT
|
|
FWIT
|
|
FWITH
|
|
FGIT
|
|
FNIT
|
|
FGITH
|
|
-- In place
|
|
FWIP
|
|
FOIP
|
|
FGIP
|
|
-- Ratios
|
|
FWCT
|
|
FWCTH
|
|
FGOR
|
|
FGORH
|
|
|
|
-- From model2
|
|
FMWPR
|
|
FMWIN
|
|
FOE
|
|
|
|
-- Pressures
|
|
FPR
|
|
|
|
BPR
|
|
1 1 1 /
|
|
1 1 2 /
|
|
1 1 3 /
|
|
1 1 4 /
|
|
1 1 5 /
|
|
1 1 6 /
|
|
1 1 7 /
|
|
1 1 8 /
|
|
1 1 9 /
|
|
1 1 10 /
|
|
2 1 10 / -- This cell is not ACTIVE
|
|
/
|
|
|
|
BSGAS
|
|
1 1 1 /
|
|
/
|
|
|
|
|
|
BSWAT
|
|
1 1 1 /
|
|
/
|
|
|
|
|
|
-- Region data
|
|
RPR
|
|
/
|
|
ROPT
|
|
/
|
|
RGPT
|
|
/
|
|
RWPT
|
|
/
|
|
RGFT
|
|
/
|
|
RWFT
|
|
/
|
|
ROIP
|
|
/
|
|
ROP
|
|
/
|
|
ROPR
|
|
/
|
|
RGPR
|
|
/
|
|
RWPR
|
|
/
|
|
RGIR
|
|
/
|
|
RGIT
|
|
/
|
|
RWIR
|
|
/
|
|
RWIT
|
|
/
|
|
RWPT
|
|
/
|
|
ROIPL
|
|
/
|
|
ROIPG
|
|
/
|
|
RGIP
|
|
/
|
|
RGIPL
|
|
/
|
|
RGIPG
|
|
/
|
|
RWIP
|
|
/
|
|
RPPO
|
|
/
|
|
|
|
-- Group data --
|
|
GPR
|
|
/
|
|
GLPR
|
|
/
|
|
GOPT
|
|
/
|
|
GGPT
|
|
/
|
|
GWPT
|
|
/
|
|
GNPT
|
|
/
|
|
GOPR
|
|
/
|
|
GGPR
|
|
/
|
|
GWPR
|
|
/
|
|
GWPRH
|
|
/
|
|
GGIR
|
|
/
|
|
GNPR
|
|
/
|
|
|
|
GNIR
|
|
/
|
|
GGIRH
|
|
/
|
|
GGIT
|
|
/
|
|
GNIT
|
|
/
|
|
GGITH
|
|
/
|
|
GWCT
|
|
/
|
|
GWCTH
|
|
/
|
|
GGOR
|
|
/
|
|
GGORH
|
|
/
|
|
GWIR
|
|
/
|
|
GWIT
|
|
/
|
|
GWIRH
|
|
/
|
|
GWITH
|
|
/
|
|
GOPRH
|
|
/
|
|
GGPRH
|
|
/
|
|
GLPRH
|
|
/
|
|
GWPTH
|
|
/
|
|
GOPTH
|
|
/
|
|
GGPTH
|
|
/
|
|
GLPTH
|
|
/
|
|
GPRG
|
|
/
|
|
GPRW
|
|
/
|
|
GOPTF
|
|
/
|
|
GOPTS
|
|
/
|
|
GOPTH
|
|
/
|
|
GOPRF
|
|
/
|
|
GOPRS
|
|
/
|
|
GOPRH
|
|
/
|
|
GGPTF
|
|
/
|
|
GGPTS
|
|
/
|
|
GGPTH
|
|
/
|
|
GGPTF
|
|
/
|
|
GGPTS
|
|
/
|
|
GGPTH
|
|
/
|
|
GGLR
|
|
/
|
|
GGLIR
|
|
/
|
|
GGLRH
|
|
/
|
|
GVPR
|
|
/
|
|
GVPT
|
|
/
|
|
GMCTP
|
|
/
|
|
GOPP
|
|
/
|
|
GVIR
|
|
/
|
|
GVIT
|
|
/
|
|
GVPRT
|
|
/
|
|
GMWPR
|
|
/
|
|
GMWIN
|
|
/
|
|
|
|
GVPR
|
|
/
|
|
|
|
GVPT
|
|
/
|
|
-- Well Data
|
|
-- Production Rates
|
|
WWPR
|
|
/
|
|
WWPRH
|
|
/
|
|
WOPR
|
|
/
|
|
WOPRH
|
|
/
|
|
WGPR
|
|
/
|
|
WNPR
|
|
/
|
|
WGPRH
|
|
/
|
|
WLPR
|
|
/
|
|
WLPRH
|
|
/
|
|
|
|
WLPT
|
|
/
|
|
|
|
WLPTH
|
|
/
|
|
|
|
WCPR
|
|
/
|
|
|
|
-- Production Cummulatives
|
|
WWPT
|
|
/
|
|
WWPTH
|
|
/
|
|
WOPT
|
|
/
|
|
WOPTH
|
|
/
|
|
WGPT
|
|
/
|
|
WGPTH
|
|
/
|
|
WNPT
|
|
/
|
|
|
|
WCPT
|
|
/
|
|
|
|
-- Tracers
|
|
--WTPRSEA
|
|
--/
|
|
--WTPTSEA
|
|
--/
|
|
-- Injection Cummulatives
|
|
-- Ratios
|
|
WWCT
|
|
/
|
|
WWCTH
|
|
/
|
|
WGOR
|
|
/
|
|
WGORH
|
|
/
|
|
WGLR
|
|
/
|
|
WGLRH
|
|
/
|
|
|
|
|
|
-- Performance
|
|
WBHP
|
|
/
|
|
WBHPH
|
|
/
|
|
WTHP
|
|
/
|
|
WTHPH
|
|
/
|
|
WPI
|
|
/
|
|
WBP
|
|
/
|
|
WBP4
|
|
/
|
|
|
|
-- from model2
|
|
WOPTF
|
|
/
|
|
WOPTS
|
|
/
|
|
WOPTH
|
|
/
|
|
WOPRS
|
|
/
|
|
WOPRF
|
|
/
|
|
WGPTF
|
|
/
|
|
WGPTS
|
|
/
|
|
WGPRF
|
|
/
|
|
WTPRS
|
|
/
|
|
WGLIR
|
|
/
|
|
WVPR
|
|
/
|
|
WVPT
|
|
/
|
|
WOPP
|
|
/
|
|
WVIR
|
|
/
|
|
WVIT
|
|
/
|
|
WMCTL
|
|
/
|
|
|
|
-- Water injection per connection
|
|
CWIR
|
|
* /
|
|
/
|
|
|
|
|
|
CGIT
|
|
* /
|
|
/
|
|
|
|
-- Production per connection
|
|
-- Using all the different ways of specifying connections here
|
|
-- as an informal test that we still get the data we want
|
|
CWPR
|
|
'W_1' 1 1 1 /
|
|
/
|
|
|
|
COPR
|
|
'W_1' /
|
|
'W_2' /
|
|
/
|
|
|
|
CGPR
|
|
'*' /
|
|
/
|
|
|
|
CNFR
|
|
'*' /
|
|
/
|
|
|
|
CNPT
|
|
'*' /
|
|
/
|
|
|
|
CNIT
|
|
'*' /
|
|
/
|
|
|
|
CWPT
|
|
'W_1' 1 1 1 /
|
|
/
|
|
|
|
COPT
|
|
'W_1' /
|
|
/
|
|
|
|
CGPT
|
|
'W_1' /
|
|
'W_2' /
|
|
/
|
|
|
|
---- Connection production rates
|
|
----CGFR
|
|
----'E-4AH' /
|
|
----/
|
|
----CWFR
|
|
----'E-2H' /
|
|
----/
|
|
|
|
SCHEDULE
|
|
|
|
GRUPTREE
|
|
'G_1' 'G' /
|
|
'G_2' 'G' /
|
|
/
|
|
|
|
|
|
WELSPECS
|
|
'W_1' 'G_1' 1 1 3.33 'OIL' 7* /
|
|
'W_2' 'G_2' 2 1 3.33 'OIL' 7* /
|
|
/
|
|
|
|
-- Completion data.
|
|
COMPDAT
|
|
-- 'Well' I J K1 K2
|
|
-- Passing 0 to I/J means they'll get the well head I/J
|
|
W_1 0 0 1 1 / -- Active index: 0
|
|
W_2 0 0 1 1 / -- Active index: 1
|
|
W_2 0 0 2 2 / -- Active index: 101
|
|
/
|
|
|
|
WCONHIST
|
|
-- history rates are set so that W_1 produces 1, W_2 produces 2 etc.
|
|
-- index.offset.
|
|
-- organised as oil-water-gas
|
|
W_1 'OPEN' ORAT 10.1 10 10.2 /
|
|
W_2 'OPEN' ORAT 20.1 20 20.2 /
|
|
/
|
|
|
|
|
|
TSTEP
|
|
-- register time steps (in days). This allows us to write *two* report steps (1
|
|
-- and 2. Without this, totals/accumulations would fail (segfault) when looking
|
|
-- up historical rates and volumes. These volumes however don't change, i.e.
|
|
-- every time step has the same set of values
|
|
10 10 /
|
|
|
|
|
|
TSTEP
|
|
10 10 /
|