CPG_SPE9.DATA: is the data file for SPE9 with a Corner Point Geometry
|
|
|
|
TOPVALUES file is not necessary for CP geometry so it has been removed.
|
|
|
|
Changes implemeted from last spe9_new files:
|
|
- In keyword COMPDAT item 8 (transmissibility factors) must be entered to get a match between Eclipse and Flow runs. This is being corrected and default values are used.
|
|
|
|
|
|
- Last line of PVTO is calculated @ 4600 psi, not 5000psi, because the SPE paper specify a way to calculate Bo 1000psi over Psta which is 3600psi (during simulation, P does not exceed 3600 psi).
|
|
|
|
- The grid has been made on Excel. |