Files
opm-data/spe9
Arne Morten Kvarving 241e708152 reduce length of restart test SPE9_CP_SHORT_RESTART
cannot reduce the amount of time steps as the SPE9_CP_SHORT file
is used for other tests, but we can restart later in the simulation
to avoid redoing as many steps
2016-11-07 12:44:34 +01:00
..
2015-09-15 11:02:47 +02:00
2015-09-15 12:06:08 +02:00

CPG_SPE9.DATA: is the data file for SPE9 with a Corner Point Geometry 

TOPVALUES file is not necessary for CP geometry so it has been removed.

Changes implemeted from last spe9_new files:
- In keyword COMPDAT item 8 (transmissibility factors) must be entered to get a match between Eclipse and Flow runs. This is being corrected and default values are used.


- Last line of PVTO is calculated @ 4600 psi, not 5000psi, because the SPE paper specify a way to calculate Bo 1000psi over Psta which is 3600psi (during simulation, P does not exceed 3600 psi).

- The grid has been made on Excel.