2017-10-05 09:55:30 -05:00
|
|
|
/*
|
|
|
|
This file is part of the Open Porous Media project (OPM).
|
|
|
|
|
|
|
|
OPM is free software: you can redistribute it and/or modify
|
|
|
|
it under the terms of the GNU General Public License as published by
|
|
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
|
|
(at your option) any later version.
|
|
|
|
|
|
|
|
OPM is distributed in the hope that it will be useful,
|
|
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
|
|
GNU General Public License for more details.
|
|
|
|
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
|
|
along with OPM. If not, see <http://www.gnu.org/licenses/>.
|
|
|
|
*/
|
|
|
|
#include "config.h"
|
|
|
|
|
|
|
|
// Define making clear that the simulator supports AMG
|
|
|
|
#define FLOW_SUPPORT_AMG 1
|
|
|
|
|
2018-09-20 03:58:27 -05:00
|
|
|
#include <flow/flow_ebos_gasoil.hpp>
|
2017-10-05 09:55:30 -05:00
|
|
|
|
2018-02-07 03:27:32 -06:00
|
|
|
#include <opm/material/common/ResetLocale.hpp>
|
2017-10-05 09:55:30 -05:00
|
|
|
#include <ewoms/models/blackoil/blackoiltwophaseindices.hh>
|
|
|
|
|
2018-02-09 06:42:16 -06:00
|
|
|
#include <opm/grid/CpGrid.hpp>
|
2019-06-20 02:09:19 -05:00
|
|
|
#include <opm/simulators/flow/SimulatorFullyImplicitBlackoilEbos.hpp>
|
|
|
|
#include <opm/simulators/flow/FlowMainEbos.hpp>
|
2017-10-05 09:55:30 -05:00
|
|
|
|
|
|
|
#if HAVE_DUNE_FEM
|
|
|
|
#include <dune/fem/misc/mpimanager.hh>
|
|
|
|
#else
|
|
|
|
#include <dune/common/parallel/mpihelper.hh>
|
|
|
|
#endif
|
|
|
|
|
2019-09-05 10:04:39 -05:00
|
|
|
namespace Opm {
|
2017-10-05 09:55:30 -05:00
|
|
|
namespace Properties {
|
|
|
|
NEW_TYPE_TAG(EclFlowGasOilProblem, INHERITS_FROM(EclFlowProblem));
|
2018-01-30 04:53:30 -06:00
|
|
|
|
2017-10-05 09:55:30 -05:00
|
|
|
//! The indices required by the model
|
2018-01-30 04:53:30 -06:00
|
|
|
SET_PROP(EclFlowGasOilProblem, Indices)
|
|
|
|
{
|
|
|
|
private:
|
|
|
|
// it is unfortunately not possible to simply use 'TypeTag' here because this leads
|
|
|
|
// to cyclic definitions of some properties. if this happens the compiler error
|
|
|
|
// messages unfortunately are *really* confusing and not really helpful.
|
|
|
|
typedef TTAG(EclFlowProblem) BaseTypeTag;
|
|
|
|
typedef typename GET_PROP_TYPE(BaseTypeTag, FluidSystem) FluidSystem;
|
|
|
|
|
|
|
|
public:
|
2019-09-05 10:04:39 -05:00
|
|
|
typedef Opm::BlackOilTwoPhaseIndices<GET_PROP_VALUE(TypeTag, EnableSolvent),
|
|
|
|
GET_PROP_VALUE(TypeTag, EnablePolymer),
|
|
|
|
GET_PROP_VALUE(TypeTag, EnableEnergy),
|
|
|
|
GET_PROP_VALUE(TypeTag, EnableFoam),
|
|
|
|
/*PVOffset=*/0,
|
|
|
|
/*disabledCompIdx=*/FluidSystem::waterCompIdx> type;
|
2018-01-30 04:53:30 -06:00
|
|
|
};
|
2017-10-05 09:55:30 -05:00
|
|
|
}}
|
|
|
|
|
|
|
|
namespace Opm {
|
2019-02-05 09:51:05 -06:00
|
|
|
void flowEbosGasOilSetDeck(double setupTime, Deck &deck, EclipseState& eclState, Schedule& schedule, SummaryConfig& summaryConfig)
|
2017-10-05 09:55:30 -05:00
|
|
|
{
|
|
|
|
typedef TTAG(EclFlowGasOilProblem) TypeTag;
|
2018-02-01 09:27:42 -06:00
|
|
|
typedef GET_PROP_TYPE(TypeTag, Vanguard) Vanguard;
|
2017-10-05 09:55:30 -05:00
|
|
|
|
2019-02-05 09:51:05 -06:00
|
|
|
Vanguard::setExternalSetupTime(setupTime);
|
add `mebos`, a multiplexed ebos variant
`mebos` works similarly as `flow`, but in contrast to `flow`, `mebos`
only creates the deck in the common code path whilst the
'EclipseState' and the other higher-level parser objects are always
created internally by the vanguard. this approach avoids code
duplication and the worst effects of parser API creep.
to avoid having to compile non-trivial compile units multiple times,
the actual code of the variants is moved into `ebos_$VARIANT.{hh,cc}`
files and the respective compile units are each put into a small
static library whilst the main function of said libraries are invoked
by either the multiplexed or the respective specialized simulator's
`main()`. This is also somewhat similar of how `flow` works, with the
difference that `mebos` uses the blackoil variant to determine the
parameters it needs to know for parsing the deck instead of
introducing a "fake" type tag for this. The rationale is to reduce
compile time compared to the "fake type tag" approach and -- to a
lesser extend -- avoid unnecessary copy-and-pasting of code. In
particular, this means that for the vast majority of cases, only one
place needs changed in the code for all `ebos` variants if, for
example, the parser API requires further objects in the future.
2019-06-11 03:22:11 -05:00
|
|
|
Vanguard::setExternalDeck(&deck);
|
|
|
|
Vanguard::setExternalEclState(&eclState);
|
2019-01-11 01:33:44 -06:00
|
|
|
Vanguard::setExternalSchedule(&schedule);
|
|
|
|
Vanguard::setExternalSummaryConfig(&summaryConfig);
|
2017-10-05 09:55:30 -05:00
|
|
|
}
|
|
|
|
|
|
|
|
|
|
|
|
// ----------------- Main program -----------------
|
2019-08-27 15:41:48 -05:00
|
|
|
int flowEbosGasOilMain(int argc, char** argv, bool outputCout, bool outputFiles)
|
2017-10-05 09:55:30 -05:00
|
|
|
{
|
|
|
|
// we always want to use the default locale, and thus spare us the trouble
|
|
|
|
// with incorrect locale settings.
|
|
|
|
Opm::resetLocale();
|
|
|
|
|
|
|
|
#if HAVE_DUNE_FEM
|
|
|
|
Dune::Fem::MPIManager::initialize(argc, argv);
|
|
|
|
#else
|
|
|
|
Dune::MPIHelper::instance(argc, argv);
|
|
|
|
#endif
|
|
|
|
|
|
|
|
Opm::FlowMainEbos<TTAG(EclFlowGasOilProblem)> mainfunc;
|
2019-08-27 15:41:48 -05:00
|
|
|
return mainfunc.execute(argc, argv, outputCout, outputFiles);
|
2017-10-05 09:55:30 -05:00
|
|
|
}
|
|
|
|
|
|
|
|
}
|