opm-simulators/opm/core/well_controls.h

148 lines
3.8 KiB
C
Raw Normal View History

/*
Copyright 2012 SINTEF ICT, Applied Mathematics.
This file is part of the Open Porous Media project (OPM).
OPM is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
OPM is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with OPM. If not, see <http://www.gnu.org/licenses/>.
*/
#ifndef OPM_WELL_CONTROLS_H_INCLUDED
#define OPM_WELL_CONTROLS_H_INCLUDED
#include <stdbool.h>
#include <opm/core/well_control_type.h>
#ifdef __cplusplus
extern "C" {
#endif
/**
* Controls for a single well.
* Each control specifies a well rate or bottom-hole pressure. Only
* one control can be active at a time, indicated by current. The
* meaning of each control's target value depends on the control type:
*
* - BHP -> target pressure in Pascal.
* - RESERVOIR_RATE -> target reservoir volume rate in cubic(meter)/second
* - SURFACE_RATE -> target surface volume rate in cubic(meter)/second
*
* The sign convention for RATE targets is as follows:
*
* - (+) Fluid flowing into reservoir, i.e. injecting.
* - (-) Fluid flowing out of reservoir, i.e. producing.
*
* For *_RATE controls, the distribution of phases used for the control
* is also needed. For example, a total rate control should have 1.0
* for each phase, whereas a control on oil rate should have 1.0 for
* the oil phase and 0.0 for the rest. For BHP controls, this is unused.
* The active control acts as an equality constraint, whereas the
* non-active controls should be interpreted as inequality
* constraints (upper or lower bounds). For instance, a PRODUCER's
* BHP constraint defines a minimum acceptable bottom-hole pressure
* value for the well.
*/
#ifdef HAVE_WELLCONTROLS
struct WellControls
{
/**
* Number of controls.
*/
int num;
int number_of_phases;
/**
* Array of control types.
*/
enum WellControlType *type;
/**
* Array of control targets.
*/
double *target;
/**
* Array of rate control distributions,
* <CODE>number_of_phases</CODE> numbers for each control
*/
double *distr;
/**
* Index of current active control.
*/
int current;
/*
The capacity allocated.
*/
int cpty;
};
#else
struct WellControls;
#endif
bool
well_controls_equal(const struct WellControls *ctrls1, const struct WellControls *ctrls2);
//int
//well_controls_reserve(int nctrl, int nphases, struct WellControls *ctrl);
struct WellControls *
well_controls_create(void);
void
well_controls_destroy(struct WellControls *ctrl);
int
well_controls_get_num(const struct WellControls *ctrl);
int
well_controls_get_cpty(const struct WellControls *ctrl);
int
well_controls_get_current( const struct WellControls * ctrl);
void
well_controls_set_current( struct WellControls * ctrl, int current);
int
well_controls_add_new(enum WellControlType type , double target , const double * distr , struct WellControls * ctrl);
enum WellControlType
well_controls_iget_type(const struct WellControls * ctrl, int control_index);
double
well_controls_iget_target(const struct WellControls * ctrl, int control_index);
const double *
well_controls_iget_distr(const struct WellControls * ctrl, int control_index);
void
well_controls_assert_number_of_phases(struct WellControls * ctrl , int number_of_phases);
void
well_controls_clear(struct WellControls * ctrl);
#ifdef __cplusplus
}
#endif
#endif /* OPM_WELL_CONTROLS_H_INCLUDED */