mirror of
https://github.com/OPM/opm-simulators.git
synced 2025-02-25 18:55:30 -06:00
Add gaslift optimization support for MSW.
Implements gas lift optimization support for multisegmented wells (MSW).
This commit is contained in:
@@ -285,7 +285,13 @@ checkThpControl_() const
|
||||
const int well_index = this->well_state_.index(this->well_name_).value();
|
||||
const Well::ProducerCMode& control_mode =
|
||||
this->well_state_.well(well_index).production_cmode;
|
||||
return control_mode == Well::ProducerCMode::THP;
|
||||
bool thp_control = control_mode == Well::ProducerCMode::THP;
|
||||
if (this->debug) {
|
||||
if (!thp_control) {
|
||||
displayDebugMessage_("Well is not under THP control, skipping iteration..");
|
||||
}
|
||||
}
|
||||
return thp_control;
|
||||
}
|
||||
|
||||
|
||||
@@ -431,6 +437,18 @@ debugShowLimitingTargets_(const LimitedRates& rates) const
|
||||
}
|
||||
}
|
||||
|
||||
void
|
||||
GasLiftSingleWellGeneric::
|
||||
debugShowProducerControlMode() const
|
||||
{
|
||||
const int well_index = this->well_state_.index(this->well_name_).value();
|
||||
const Well::ProducerCMode& control_mode =
|
||||
this->well_state_.well(well_index).production_cmode;
|
||||
const std::string msg = fmt::format("Current control mode is: {}",
|
||||
Well::ProducerCMode2String(control_mode));
|
||||
displayDebugMessage_(msg);
|
||||
}
|
||||
|
||||
void
|
||||
GasLiftSingleWellGeneric::
|
||||
debugShowStartIteration_(double alq, bool increase, double oil_rate)
|
||||
@@ -1139,6 +1157,7 @@ std::unique_ptr<GasLiftWellState>
|
||||
GasLiftSingleWellGeneric::
|
||||
runOptimizeLoop_(bool increase)
|
||||
{
|
||||
if (this->debug) debugShowProducerControlMode();
|
||||
std::unique_ptr<GasLiftWellState> ret_value; // nullptr initially
|
||||
auto rates = getInitialRatesWithLimit_();
|
||||
if (!rates) return ret_value;
|
||||
@@ -1160,7 +1179,11 @@ runOptimizeLoop_(bool increase)
|
||||
}
|
||||
|
||||
OptimizeState state {*this, increase};
|
||||
if (!checkThpControl_()) {
|
||||
auto temp_alq = cur_alq;
|
||||
if (checkThpControl_()) {
|
||||
if (this->debug) debugShowStartIteration_(temp_alq, increase, new_rates.oil);
|
||||
}
|
||||
else {
|
||||
// If the well is not under THP control, we can still use the previous
|
||||
// initial adjustment of ALQ by using the well's THP limit to calculate
|
||||
// BHP and then well rates from that.
|
||||
@@ -1169,8 +1192,6 @@ runOptimizeLoop_(bool increase)
|
||||
// Then gaslift can be reduced while still keeping the group target.
|
||||
state.stop_iteration = true;
|
||||
}
|
||||
auto temp_alq = cur_alq;
|
||||
if (this->debug) debugShowStartIteration_(temp_alq, increase, new_rates.oil);
|
||||
while (!state.stop_iteration && (++state.it <= this->max_iterations_)) {
|
||||
if (state.checkRatesViolated(new_rates)) break;
|
||||
if (state.checkAlqOutsideLimits(temp_alq, new_rates.oil)) break;
|
||||
@@ -1524,11 +1545,11 @@ checkAlqOutsideLimits(double alq, [[maybe_unused]] double oil_rate)
|
||||
else { // we are decreasing lift gas
|
||||
if ( alq == 0 ) {
|
||||
ss << "ALQ is zero, cannot decrease further. Stopping iteration.";
|
||||
return true;
|
||||
result = true;
|
||||
}
|
||||
else if ( alq < 0 ) {
|
||||
ss << "Negative ALQ: " << alq << ". Stopping iteration.";
|
||||
return true;
|
||||
result = true;
|
||||
}
|
||||
// NOTE: A negative min_alq_ means: allocate at least enough lift gas
|
||||
// to enable the well to flow, see WLIFTOPT item 5.
|
||||
|
||||
Reference in New Issue