mirror of
https://github.com/OPM/opm-simulators.git
synced 2025-02-25 18:55:30 -06:00
Fixed whitespace
This commit is contained in:
parent
68428ad856
commit
6365579866
@ -57,22 +57,22 @@ namespace Opm
|
||||
for (int p = 0; p < np; ++p) {
|
||||
wellrates_[np*w + p] = 0.0;
|
||||
}
|
||||
// 2. Bhp: assign bhp equal to bhp control, if
|
||||
// applicable, otherwise assign equal to
|
||||
// first perforation cell pressure.
|
||||
// 2. Bhp: assign bhp equal to bhp control, if
|
||||
// applicable, otherwise assign equal to
|
||||
// first perforation cell pressure.
|
||||
if (well_controls_get_current_type(ctrl) == BHP) {
|
||||
bhp_[w] = well_controls_get_current_target( ctrl );
|
||||
} else {
|
||||
const int first_cell = wells->well_cells[wells->well_connpos[w]];
|
||||
bhp_[w] = state.pressure()[first_cell];
|
||||
}
|
||||
// 3. Thp: assign thp equal to thp control, if applicable,
|
||||
// otherwise assign equal to bhp value.
|
||||
}
|
||||
// 3. Thp: assign thp equal to thp control, if applicable,
|
||||
// otherwise assign equal to bhp value.
|
||||
if (well_controls_get_current_type(ctrl) == THP) {
|
||||
thp_[w] = well_controls_get_current_target( ctrl );
|
||||
} else {
|
||||
thp_[w] = bhp_[w];
|
||||
}
|
||||
}
|
||||
} else {
|
||||
// Open well:
|
||||
// 1. Rates: initialize well rates to match controls
|
||||
@ -97,26 +97,26 @@ namespace Opm
|
||||
|
||||
// 2. Bhp: initialize bhp to be target pressure if
|
||||
// bhp-controlled well, otherwise set to a
|
||||
// little above or below (depending on if
|
||||
// the well is an injector or producer)
|
||||
// pressure in first perforation cell.
|
||||
if (well_controls_get_current_type(ctrl) == BHP) {
|
||||
bhp_[w] = well_controls_get_current_target( ctrl );
|
||||
} else {
|
||||
const int first_cell = wells->well_cells[wells->well_connpos[w]];
|
||||
const double safety_factor = (wells->type[w] == INJECTOR) ? 1.01 : 0.99;
|
||||
bhp_[w] = safety_factor*state.pressure()[first_cell];
|
||||
}
|
||||
// little above or below (depending on if
|
||||
// the well is an injector or producer)
|
||||
// pressure in first perforation cell.
|
||||
if (well_controls_get_current_type(ctrl) == BHP) {
|
||||
bhp_[w] = well_controls_get_current_target( ctrl );
|
||||
} else {
|
||||
const int first_cell = wells->well_cells[wells->well_connpos[w]];
|
||||
const double safety_factor = (wells->type[w] == INJECTOR) ? 1.01 : 0.99;
|
||||
bhp_[w] = safety_factor*state.pressure()[first_cell];
|
||||
}
|
||||
|
||||
// 3. Thp: assign thp equal to thp control, if applicable,
|
||||
// otherwise assign equal to bhp value.
|
||||
if (well_controls_get_current_type(ctrl) == THP) {
|
||||
thp_[w] = well_controls_get_current_target( ctrl );
|
||||
} else {
|
||||
thp_[w] = bhp_[w];
|
||||
}
|
||||
}
|
||||
}
|
||||
// 3. Thp: assign thp equal to thp control, if applicable,
|
||||
// otherwise assign equal to bhp value.
|
||||
if (well_controls_get_current_type(ctrl) == THP) {
|
||||
thp_[w] = well_controls_get_current_target( ctrl );
|
||||
} else {
|
||||
thp_[w] = bhp_[w];
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
// The perforation rates and perforation pressures are
|
||||
// not expected to be consistent with bhp_ and wellrates_
|
||||
|
Loading…
Reference in New Issue
Block a user