when a valve is shut, the rate and pressure drop will be zero
This commit is contained in:
parent
5b2d1ca5ec
commit
64143cd417
@ -1554,6 +1554,18 @@ assembleICDPressureEq(const int seg,
|
||||
// top segment can not be a spiral ICD device
|
||||
assert(seg != 0);
|
||||
|
||||
if(this->segmentSet()[seg].segmentType() == Segment::SegmentType::VALVE) {
|
||||
const Valve& valve = this->segmentSet()[seg].valve();
|
||||
if (valve.status() == Opm::ICDStatus::SHUT) { // we switch here to be a zero rate equation
|
||||
resWell_[seg][SPres] = this->primary_variables_evaluation_[seg][GTotal].value();
|
||||
duneD_[seg][seg][SPres][GTotal] = 1.;
|
||||
|
||||
auto& ws = well_state.well(baseif_.indexOfWell());
|
||||
ws.segments.pressure_drop_friction[seg] = 0.;
|
||||
return;
|
||||
}
|
||||
}
|
||||
|
||||
// the pressure equation is something like
|
||||
// p_seg - deltaP - p_outlet = 0.
|
||||
// the major part is how to calculate the deltaP
|
||||
|