Handle two possible cases where current control is -1.

This commit is contained in:
Atgeirr Flø Rasmussen 2019-08-12 14:49:52 +02:00
parent 9f1e3465db
commit 8438e84db1
2 changed files with 14 additions and 1 deletions

View File

@ -1207,7 +1207,7 @@ namespace Opm
const WellControls* wc = well_controls_;
const double* distr = well_controls_get_current_distr(wc);
if (well_controls_get_current_type(wc) == RESERVOIR_RATE) {
if (well_controls_get_current(wc) != -1 && well_controls_get_current_type(wc) == RESERVOIR_RATE) {
if (has_solvent && phaseIdx == contiSolventEqIdx ) {
typedef Ewoms::BlackOilSolventModule<TypeTag> SolventModule;
double coeff = 0;

View File

@ -109,6 +109,19 @@ namespace Opm
const int first_cell = wells->well_cells[wells->well_connpos[w]];
bhp_[w] = cellPressures[first_cell];
}
} else if (well_controls_get_current(ctrl) == -1) {
// Well under group control.
// 1. Rates: assign zero well rates.
for (int p = 0; p < np; ++p) {
wellrates_[np*w + p] = 0.0;
}
// 2. Bhp: initialize bhp to be a
// little above or below (depending on if
// the well is an injector or producer)
// pressure in first perforation cell.
const int first_cell = wells->well_cells[wells->well_connpos[w]];
const double safety_factor = (wells->type[w] == INJECTOR) ? 1.01 : 0.99;
bhp_[w] = safety_factor*cellPressures[first_cell];
} else {
// Open well:
// 1. Rates: initialize well rates to match controls