mirror of
https://github.com/OPM/opm-simulators.git
synced 2025-02-25 18:55:30 -06:00
Fix logic related to open/shut wells initialisation.
This commit is contained in:
parent
c0fd117103
commit
a13f7b990f
@ -48,34 +48,53 @@ namespace Opm
|
||||
for (int w = 0; w < nw; ++w) {
|
||||
assert((wells->type[w] == INJECTOR) || (wells->type[w] == PRODUCER));
|
||||
const WellControls* ctrl = wells->ctrls[w];
|
||||
// Initialize bhp to be target pressure if
|
||||
// bhp-controlled well, otherwise set to a little
|
||||
// above or below (depending on if the well is an
|
||||
// injector or producer) pressure in first perforation
|
||||
// cell.
|
||||
if (well_controls_well_is_shut(ctrl) || (well_controls_get_current_type(ctrl) != BHP)) {
|
||||
const int first_cell = wells->well_cells[wells->well_connpos[w]];
|
||||
const double safety_factor = (wells->type[w] == INJECTOR) ? 1.01 : 0.99;
|
||||
bhp_[w] = safety_factor*state.pressure()[first_cell];
|
||||
} else {
|
||||
bhp_[w] = well_controls_get_current_target( ctrl );
|
||||
}
|
||||
|
||||
// Initialize well rates to match controls if type is SURFACE_RATE.
|
||||
// Otherwise, we cannot set the correct value here, so we assign
|
||||
// a small rate with the correct sign so that any logic depending on
|
||||
// that sign will work as expected.
|
||||
if (well_controls_well_is_open( ctrl ) && (well_controls_get_current_type(ctrl) == SURFACE_RATE)) {
|
||||
const double rate_target = well_controls_get_current_target(ctrl);
|
||||
const double * distr = well_controls_get_current_distr( ctrl );
|
||||
if (well_controls_well_is_shut(ctrl)) {
|
||||
// Shut well:
|
||||
// 1. Assign zero well rates.
|
||||
for (int p = 0; p < np; ++p) {
|
||||
wellrates_[np*w + p] = rate_target * distr[p];
|
||||
wellrates_[np*w + p] = 0.0;
|
||||
}
|
||||
// 2. Assign bhp equal to bhp control, if
|
||||
// applicable, otherwise assign equal to
|
||||
// first perforation cell pressure.
|
||||
if (well_controls_get_current_type(ctrl) == BHP) {
|
||||
bhp_[w] = well_controls_get_current_target( ctrl );
|
||||
} else {
|
||||
const int first_cell = wells->well_cells[wells->well_connpos[w]];
|
||||
bhp_[w] = state.pressure()[first_cell];
|
||||
}
|
||||
} else {
|
||||
const double small_rate = 1e-14;
|
||||
const double sign = (wells->type[w] == INJECTOR) ? 1.0 : -1.0;
|
||||
for (int p = 0; p < np; ++p) {
|
||||
wellrates_[np*w + p] = small_rate * sign;
|
||||
// Open well:
|
||||
// 1. Initialize well rates to match controls
|
||||
// if type is SURFACE_RATE. Otherwise, we
|
||||
// cannot set the correct value here, so we
|
||||
// assign a small rate with the correct
|
||||
// sign so that any logic depending on that
|
||||
// sign will work as expected.
|
||||
if (well_controls_get_current_type(ctrl) == SURFACE_RATE) {
|
||||
const double rate_target = well_controls_get_current_target(ctrl);
|
||||
const double * distr = well_controls_get_current_distr( ctrl );
|
||||
for (int p = 0; p < np; ++p) {
|
||||
wellrates_[np*w + p] = rate_target * distr[p];
|
||||
}
|
||||
} else {
|
||||
const double small_rate = 1e-14;
|
||||
const double sign = (wells->type[w] == INJECTOR) ? 1.0 : -1.0;
|
||||
for (int p = 0; p < np; ++p) {
|
||||
wellrates_[np*w + p] = small_rate * sign;
|
||||
}
|
||||
}
|
||||
// 2. Initialize bhp to be target pressure if
|
||||
// bhp-controlled well, otherwise set to a
|
||||
// little above or below (depending on if
|
||||
// the well is an injector or producer)
|
||||
// pressure in first perforation cell.
|
||||
if (well_controls_get_current_type(ctrl) == BHP) {
|
||||
bhp_[w] = well_controls_get_current_target( ctrl );
|
||||
} else {
|
||||
const int first_cell = wells->well_cells[wells->well_connpos[w]];
|
||||
const double safety_factor = (wells->type[w] == INJECTOR) ? 1.01 : 0.99;
|
||||
bhp_[w] = safety_factor*state.pressure()[first_cell];
|
||||
}
|
||||
}
|
||||
}
|
||||
|
Loading…