diff --git a/opm/core/wells/WellsManager.cpp b/opm/core/wells/WellsManager.cpp index 247fd06d6..c3970e69e 100644 --- a/opm/core/wells/WellsManager.cpp +++ b/opm/core/wells/WellsManager.cpp @@ -544,10 +544,7 @@ namespace Opm } if (ok) { - // Always append a BHP control. - // If no explicit BHP control given, use a 1 atm control. - const bool has_explicit_limit = productionProperties.hasProductionControl(WellProducer::BHP); - const double bhp_limit = has_explicit_limit ? productionProperties.BHPLimit : unit::convert::from(1.0, unit::atm); + const double bhp_limit = productionProperties.BHPLimit; control_pos[WellsManagerDetail::ProductionControl::BHP] = well_controls_get_num(w_->ctrls[well_index]); ok = append_well_controls(BHP, bhp_limit,