tightenging tolerance for MS cases for regression test

This commit is contained in:
Kai Bao 2020-03-08 17:41:00 +01:00
parent 5b457cbbd6
commit f44c441acb

View File

@ -255,7 +255,8 @@ add_test_compareECLFiles(CASENAME msw_3d_hfa
FILENAME 3D_MSW
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${rel_tol})
REL_TOL ${rel_tol}
TEST_ARGS --tolerance-pressure-ms-wells=10.)
add_test_compareECLFiles(CASENAME polymer_oilwater
FILENAME 2D_OILWATER_POLYMER
@ -296,7 +297,8 @@ add_test_compareECLFiles(CASENAME msw_model_1
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${rel_tol}
DIR model1)
DIR model1
TEST_ARGS --solver-max-time-step-in-days=5.0)
add_test_compareECLFiles(CASENAME base_model_1
FILENAME BASE_MODEL_1
@ -310,7 +312,8 @@ add_test_compareECLFiles(CASENAME faults_model_1
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${rel_tol}
DIR model1)
DIR model1
TEST_ARGS --solver-max-time-step-in-days=5.0)
add_test_compareECLFiles(CASENAME base_model2
FILENAME 0_BASE_MODEL2