WellsManager now handles multiple WELSPECS, WCONINJE, WCONPROD-lines referring to the same well.
This is mostly relevant for schedule handling. The last occurence of a well is the one used.
This commit is contained in:
parent
98de826397
commit
f452c4c33c
@ -42,6 +42,7 @@ namespace
|
||||
// double target;
|
||||
double reference_bhp_depth;
|
||||
// Opm::InjectionSpecification::InjectorType injected_phase;
|
||||
int welspecsline;
|
||||
};
|
||||
|
||||
|
||||
@ -224,26 +225,45 @@ namespace Opm
|
||||
|
||||
// For easy lookup:
|
||||
std::map<std::string, int> well_names_to_index;
|
||||
typedef std::map<std::string, int>::const_iterator WNameIt;
|
||||
|
||||
// Get WELSPECS data
|
||||
// Get WELSPECS data.
|
||||
// It is allowed to have multiple lines corresponding to
|
||||
// the same well, in which case the last one encountered
|
||||
// is the one used.
|
||||
const WELSPECS& welspecs = deck.getWELSPECS();
|
||||
const int num_wells = welspecs.welspecs.size();
|
||||
well_names.reserve(num_wells);
|
||||
well_data.reserve(num_wells);
|
||||
wellperf_data.resize(num_wells);
|
||||
for (int w = 0; w < num_wells; ++w) {
|
||||
well_names.push_back(welspecs.welspecs[w].name_);
|
||||
const int num_welspecs = welspecs.welspecs.size();
|
||||
well_names.reserve(num_welspecs);
|
||||
well_data.reserve(num_welspecs);
|
||||
for (int w = 0; w < num_welspecs; ++w) {
|
||||
// First check if this well has already been encountered.
|
||||
// If so, we modify it's data instead of appending a new well
|
||||
// to the well_data and well_names vectors.
|
||||
const std::string& name = welspecs.welspecs[w].name_;
|
||||
const double refdepth = welspecs.welspecs[w].datum_depth_BHP_;
|
||||
WNameIt wit = well_names_to_index.find(name);
|
||||
if (wit == well_names_to_index.end()) {
|
||||
// New well, append data.
|
||||
well_names_to_index[welspecs.welspecs[w].name_] = well_data.size();
|
||||
well_names.push_back(name);
|
||||
WellData wd;
|
||||
// If negative (defaulted), set refdepth to a marker
|
||||
// value, will be changed after getting perforation
|
||||
// data to the centroid of the cell of the top well
|
||||
// perforation.
|
||||
wd.reference_bhp_depth = (refdepth < 0.0) ? -1e100 : refdepth;
|
||||
wd.welspecsline = w;
|
||||
well_data.push_back(wd);
|
||||
well_names_to_index[welspecs.welspecs[w].name_] = w;
|
||||
well_data.back().reference_bhp_depth = welspecs.welspecs[w].datum_depth_BHP_;
|
||||
if (welspecs.welspecs[w].datum_depth_BHP_ < 0.0) {
|
||||
// Set refdepth to a marker value, will be changed
|
||||
// after getting perforation data to the centroid of
|
||||
// the cell of the top well perforation.
|
||||
well_data.back().reference_bhp_depth = -1e100;
|
||||
} else {
|
||||
// Existing well, change data.
|
||||
const int wix = wit->second;
|
||||
well_data[wix].reference_bhp_depth = (refdepth < 0.0) ? -1e100 : refdepth;
|
||||
well_data[wix].welspecsline = w;
|
||||
}
|
||||
}
|
||||
const int num_wells = well_data.size();
|
||||
wellperf_data.resize(num_wells);
|
||||
|
||||
|
||||
// global_cell is a map from compressed cells to Cartesian grid cells.
|
||||
// We must make the inverse lookup.
|
||||
@ -263,6 +283,8 @@ namespace Opm
|
||||
}
|
||||
|
||||
// Get COMPDAT data
|
||||
// It is *not* allowed to have multiple lines corresponding to
|
||||
// the same perforation!
|
||||
const COMPDAT& compdat = deck.getCOMPDAT();
|
||||
const int num_compdat = compdat.compdat.size();
|
||||
for (int kw = 0; kw < num_compdat; ++kw) {
|
||||
@ -279,7 +301,7 @@ namespace Opm
|
||||
if (well_names[wix].compare(0,len, name) == 0) { // equal
|
||||
// Extract corresponding WELSPECS defintion for
|
||||
// purpose of default location specification.
|
||||
const WelspecsLine& wspec = welspecs.welspecs[wix];
|
||||
const WelspecsLine& wspec = welspecs.welspecs[well_data[wix].welspecsline];
|
||||
|
||||
// We have a matching name.
|
||||
int ix = compdat.compdat[kw].grid_ind_[0] - 1;
|
||||
@ -345,7 +367,7 @@ namespace Opm
|
||||
ASSERT(grid.dimensions == 3);
|
||||
for (int w = 0; w < num_wells; ++w) {
|
||||
num_perfs += wellperf_data[w].size();
|
||||
if (well_data[w].reference_bhp_depth == -1e100) {
|
||||
if (well_data[w].reference_bhp_depth < 0.0) {
|
||||
// It was defaulted. Set reference depth to minimum perforation depth.
|
||||
double min_depth = 1e100;
|
||||
int num_wperfs = wellperf_data[w].size();
|
||||
@ -371,8 +393,7 @@ namespace Opm
|
||||
if (it != well_names_to_index.end()) {
|
||||
const int well_index = it->second;
|
||||
well_data[well_index].type = INJECTOR;
|
||||
}
|
||||
else {
|
||||
} else {
|
||||
THROW("Unseen well name: " << lines[i].well_ << " first seen in WCONINJE");
|
||||
}
|
||||
}
|
||||
@ -411,6 +432,9 @@ namespace Opm
|
||||
}
|
||||
|
||||
// Get WCONINJE data, add injection controls to wells.
|
||||
// It is allowed to have multiple lines corresponding to
|
||||
// the same well, in which case the last one encountered
|
||||
// is the one used.
|
||||
if (deck.hasField("WCONINJE")) {
|
||||
const WCONINJE& wconinjes = deck.getWCONINJE();
|
||||
const int num_wconinjes = wconinjes.wconinje.size();
|
||||
@ -433,6 +457,9 @@ namespace Opm
|
||||
}
|
||||
|
||||
// Add all controls that are present in well.
|
||||
// First we must clear existing controls, in case the
|
||||
// current WCONINJE line is modifying earlier controls.
|
||||
clear_well_controls(wix, w_);
|
||||
int ok = 1;
|
||||
int control_pos[5] = { -1, -1, -1, -1, -1 };
|
||||
if (ok && wci_line.surface_flow_max_rate_ >= 0.0) {
|
||||
@ -494,6 +521,9 @@ namespace Opm
|
||||
}
|
||||
|
||||
// Get WCONPROD data
|
||||
// It is allowed to have multiple lines corresponding to
|
||||
// the same well, in which case the last one encountered
|
||||
// is the one used.
|
||||
if (deck.hasField("WCONPROD")) {
|
||||
const WCONPROD& wconprods = deck.getWCONPROD();
|
||||
const int num_wconprods = wconprods.wconprod.size();
|
||||
@ -513,6 +543,9 @@ namespace Opm
|
||||
THROW("Found WCONPROD entry for a non-producer well: " << well_names[wix]);
|
||||
}
|
||||
// Add all controls that are present in well.
|
||||
// First we must clear existing controls, in case the
|
||||
// current WCONPROD line is modifying earlier controls.
|
||||
clear_well_controls(wix, w_);
|
||||
int control_pos[9] = { -1, -1, -1, -1, -1, -1, -1, -1, -1 };
|
||||
int ok = 1;
|
||||
if (ok && wcp_line.oil_max_rate_ >= 0.0) {
|
||||
|