so far, the actual specializations of the simulator were compiled into
the `libopmsimulators` library and the build of the glue code
(`flow.cpp`) thus needed to be deferred until the library was fully
built. Since the compilation of the glue code requires a full property
hierarchy for handling command line parameters, this arrangement
significantly increases the build time for systems with a sufficient
number of parallel build processes. ("sufficient" here means 8 or more
threads, i.e., a quadcore system with hyperthreading is sufficient
provided that it has enough main memory.)
the new approach is not to include these objects in
`libopmsimulators`, but to directly deal with them in the `flow`
binary. this allows all of them and the glue code to be compiled in
parallel.
compilation time on my machine before this change:
```
> touch ../opm/autodiff/BlackoilModelEbos.hpp; time make -j32 flow 2> /dev/null
Scanning dependencies of target opmsimulators
[ 2%] Building CXX object CMakeFiles/opmsimulators.dir/opm/simulators/flow_ebos_gasoil.cpp.o
[ 2%] Building CXX object CMakeFiles/opmsimulators.dir/opm/simulators/flow_ebos_oilwater.cpp.o
[ 2%] Building CXX object CMakeFiles/opmsimulators.dir/opm/simulators/flow_ebos_blackoil.cpp.o
[ 2%] Building CXX object CMakeFiles/opmsimulators.dir/opm/simulators/flow_ebos_solvent.cpp.o
[ 4%] Building CXX object CMakeFiles/opmsimulators.dir/opm/simulators/flow_ebos_polymer.cpp.o
[ 6%] Building CXX object CMakeFiles/opmsimulators.dir/opm/simulators/flow_ebos_energy.cpp.o
[ 6%] Building CXX object CMakeFiles/opmsimulators.dir/opm/simulators/flow_ebos_oilwater_polymer.cpp.o
[ 6%] Linking CXX static library lib/libopmsimulators.a
[ 97%] Built target opmsimulators
Scanning dependencies of target flow
[100%] Building CXX object CMakeFiles/flow.dir/examples/flow.cpp.o
[100%] Linking CXX executable bin/flow
[100%] Built target flow
real 1m45.692s
user 8m47.195s
sys 0m11.533s
```
after:
```
> touch ../opm/autodiff/BlackoilModelEbos.hpp; time make -j32 flow 2> /dev/null
[ 91%] Built target opmsimulators
Scanning dependencies of target flow
[ 93%] Building CXX object CMakeFiles/flow.dir/flow/flow.cpp.o
[ 95%] Building CXX object CMakeFiles/flow.dir/flow/flow_ebos_gasoil.cpp.o
[ 97%] Building CXX object CMakeFiles/flow.dir/flow/flow_ebos_oilwater_polymer.cpp.o
[100%] Building CXX object CMakeFiles/flow.dir/flow/flow_ebos_polymer.cpp.o
[100%] Building CXX object CMakeFiles/flow.dir/flow/flow_ebos_oilwater.cpp.o
[100%] Building CXX object CMakeFiles/flow.dir/flow/flow_ebos_solvent.cpp.o
[100%] Building CXX object CMakeFiles/flow.dir/flow/flow_ebos_blackoil.cpp.o
[100%] Building CXX object CMakeFiles/flow.dir/flow/flow_ebos_energy.cpp.o
[100%] Linking CXX executable bin/flow
[100%] Built target flow
real 1m21.597s
user 8m49.476s
sys 0m10.973s
```
(this corresponds to a ~20% reduction of the time spend on waiting for
the compiler.)
The problem was only present if UMFPack was not found and therefore
FLOW_SUPPORT_AMG was defined to true. In that case we experienced compile
errors in a source branch that would never be executed. Therefore we remove
the code there and throw an exception.
i.e., mine (openSuse Tumbleweed). the problem seems to be that the
specialization of `ISTLSolver::constructAMGPrecond()` is ambiguous and
some compilers seem to be more strict about this than others. Simply
removing the problematic method seems to work fine.
That said, for non-legacy `flow` this codepath is not taken at runtime
anyway because the `ISTLSolverEbos` class is used!?
Previously the regex issued warning for all files containing ".[0-9]*." in the name
in the output directory. That was too general and created more warnings than we wanted.
This fixes fallout from the merge of PR #1512. Since then the
ParallelFileMerger was always given the current directory even if
another output directory was requested. This resulted in
CASENAME.<procid>.<ext> files in that directory never being merged and removed.
Now the ParallelFileMerger gets the output directory path again.
It should be --milu-variant and is it now. Maybe the parameter system
could be a bit smart and detect consecutive upper case letters and treat
them correctly.
- Change the brief description slightly
- Do not print anything anymore if there are no unused parameters
- Change the boiler plate text for printing the parameters to the
PRT/DBG files
in part, this has been requested by [at]atgeirr.