If guiderate is violated change to group controll.
Note that a factor 1.01 is added to minimize oscilations.
Fix missing multiplication with group efficiency when accumulating guiderates
Renames some methods and variables to reflect that the well is no
longer necessarily a StandardWell. It can be either a MultisegmentWell
or a StandardWell. This should avoid confusion about the nature of
the variable.
If a well is under a group that is limited by a target, it should use as little gaslift as possible.
The reduction algorithm will reduce the gaslift of the well as long as the groups potential is above the groups target.
Introduces two new data types BasicRates and LimitedRates to capture
oil, gas, and water rates, and whether they have been limited by well
or group targets. This reduces the number of variables that are passed
to and returned from various methods and thus makes the code easier to
read.
There was a fallout when skipping concating these files to the
default ones (PR #1708). We should also have deactivated creating
these files at all. As a result these files appeared in all parallel
runs that were aborted.
This change now prevents creating and logging to these files in
parallel in a default
run (--enable-parallel-logging-fallout-warning=false).
Developers can still activate logging and concating to see whether
everything is only logged on the io process by passing
--enable-parallel-logging-fallout-warning=true.
Closes 3725
Introduces a gaslift debugging variable in ALQState in WellState. This
variable will persist between timesteps in contrast to when debugging
variables are defined in GasLiftSingleWell, GasLiftGroupState, or GasLiftStage2.
Currently only an integer variable debug_counter is added to ALQState,
which can be used as follows: First debugging is switched on globally
for BlackOilWellModel, GasLiftSingleWell, GasLiftGroupState, and
GasLiftStage2 by setting glift_debug to a true value in BlackOilWellModelGeneric.
Then, the following debugging code can be added to e.g. one of
GasLiftSingleWell, GasLiftGroupState, or GasLiftStage2 :
auto count = debugUpdateGlobalCounter_();
if (count == some_integer) {
displayDebugMessage_("stop here");
}
Here, the integer "some_integer" is determined typically by looking at
the debugging output of a previous run. This can be done since the
call to debugUpdateGlobalCounter_() will print out the current value
of the counter and then increment the counter by one. And it will be
easy to recognize these values in the debug ouput. If you find a place
in the output that looks suspect, just take a note of the counter
value in the output around that point and insert the value for
"some_integer", then after recompiling the code with the desired value
for "some_integer", it is now easy to set a breakpoint in GDB at the
line
displayDebugMessage_("stop here").
shown in the above snippet. This should improve the ability to quickly
to set a breakpoint in GDB around at a given time and point in the simulation.
This is needed to get consistent estimates for the summary vectors
* {F,G,W}OP{R,T}{F,S} -- Free/Vaporized Oil Production
* {F,G,W}GP{R,T}{F,S} -- Free/Dissolved Gas Production
in the case of distributed wells.
Thanks to [at]blattms for the suggested fix.