This commit renames the previously introduced command line option
ExtraConvergenceOutput (--extra-convergence-output) into the more
descriptive
OutputExtraConvergenceInfo (--output-extra-convergence-info)
Suggested by: [at]OPMUSER
This commit enables outputting non-linear convergence metrics, i.e.,
the MB and CNV values, per phase, for each non-linear iteration in
each timestep. If the user passes the option value "iterations" to
the --extra-convergence-output command line option, this commit will
create a new output file, CASE.INFOITER, that holds
* report step
* time step within that report step
* elapsed time
* MB and CNV values per phase
* well convergence status
for each non-linear iteration.
We use an asynchronous file writing procedure and confer ownership
of the report step's unprocessed convergence reports to this
procedure just before the end of
SimulatorFullyImplicitBlackoilEbos::runStep()
At that point, the convergence reports are about to go out of scope.
The asynchronous protocol uses a dedicated queue of output requests,
class ConvergenceReportQueue, into which the producer-i.e., member
function runStep()-inserts new convergence reports and from which
the output thread, ConvergenceOutputThread::writeASynchronous(),
retrieves those requests before writing the file data.
This commit introduces a new helper class,
ConvergenceOutputConfiguration
which parses comma separated option strings into a runtime
configuration object for whether to output additional convergence
information and, if so, what information to output.
Supported option string values are
* "none" -- Dont want any additional convergence output.
* "steps" -- Want additional convergence output pertaining to the
converged solution at the end of each timestep.
* "iterations" -- Want additional convergence output pertaining to each
non-linar ieration in each timestep.
Option value "none" overrides all other options. In other words, if the
user requests "none", then there will be no additional convergence
output, even if there are other options in the option string.
We add a new option, ExtraConvergenceOutput (command line option
--extra-convergence-output), which takes a string argument expected
to be a comma separated combination of these options. The default
value is "none". Finally, make the INFOSTEP file output conditional
on the user supplying "steps" as an argument to the new option.
This enables outputting a formatted record of the limiting MB and
CNV quantities as time and non-linear iterations progress. This, in
turn, is intended for diagnostic and analysis purposes and will not
be output unless specifically requested.
In particular, add a new type,
ConvergenceReport::ReservoirConvergenceMetric
which captures the convergence metric type (MB or CNV) along with
the associate phase and numerical value of the convergence metric.
We add a vector of these convergence metric objects as a new data
member of the ConvergenceReport.
Finally, foreshadowing the intended use case, also store the report
time in the ConvergenceReport object.
Needed to prevent an exception. Apparently both the value and usage
sting must match each time we register a parameter no matter
whether the template parameters differs or not.
- use imported target for linking
- use separate damaris cmake script
- handle HAVE_DAMARIS config variable in the usual way
fixing issues when user does not provide an outputDir via a command_line
avoid adding damaris's command lines when we dont have damaris
This is necessary because when using Damaris we must have the output dir ready
when we initialize Damaris. In the existing code, this was ensured only
from the setupLogging() call.
Damaris initialization is added after InitMpi but before starting the simulation. Damaris will invoke a separate core for writing in
parallel and leave the rest of cores for the simulator. The main changes are in main where start_damaris and then in eclwriterm where
we use damaris to output the PRESSURE. To test Damaris one can use --enable-damaris-output=true and to use parallel HDF5 one can use
--enable-async-damaris-output=true (false is the default choice)
This is only instantiated for two-phase gas/oil and for 3-phase blackoil.
Runtime safeguards have been added to avoid the mistake of running with
a simulator combination that silently ignores DIFFUSE.
This is one of several PRs that will rename some command line parameters for greater consistency, as agreed with Atgeirr in #4096
Here we rename FlowNewtonMinIterations to NewtonMinIterations
Moving it ensures it is also done for restart simulation runs. Without
this, the well model will actually initialize the IQs, but only for
owned cells, not overlap/ghost cells, which caused parallel failure.