This test exposes a bug in GroupStateHelper::checkGroupConstraintsProd()
where the addback calculation uses the accumulated efficiency factor
instead of the partial efficiency factor at local_reduction_level.
Test setup:
- Group hierarchy: FIELD -> PLAT (E=0.9) -> MANI (E=0.8) / MANI2 (E=0.7)
- MANI has individual ORAT control, PLAT has guide rate
- WELL-A produces 10000 SM3/day under MANI
The bug causes:
- Addback uses 0.72 (E_MANI * E_PLAT) instead of 0.8 (E_MANI)
- This results in scale = 0.9465 (false constraint violation)
- Correct calculation would give scale = 1.0288 (no violation)
The test currently passes with the buggy expected values. A subsequent
commit will fix the bug and update the test expectations.
replacing it with a new PhaseUsageInfo and FluidSystem, both of which
are using the same implementation of PhaseUsageInfo, and only one set of
indices is used. Currently, it is the BlackOilDefaultFluidSystemIndices.
Now that the AD (Evaluation) primary variables in the well classes
are always updated whenever the value primary variables are, we
no longer need to remember to explicitly update them, simplifying
the code and enabling removal of functions.
The init() function of the primary variable classes have been renamed
to setEvaluationsFromValues() and made private.
without considering the iteration number. Because of the different
implementaion from other simulators, it is difficult to honour
procedure-dependent parameters.
It only makes sense to try to optimize the distribution of lift gas if
the amount of lift gas is constrained either by the maximum allowed
gaslift or total gas or the group is under individual control.
Introduces a gaslift debugging variable in ALQState in WellState. This
variable will persist between timesteps in contrast to when debugging
variables are defined in GasLiftSingleWell, GasLiftGroupState, or GasLiftStage2.
Currently only an integer variable debug_counter is added to ALQState,
which can be used as follows: First debugging is switched on globally
for BlackOilWellModel, GasLiftSingleWell, GasLiftGroupState, and
GasLiftStage2 by setting glift_debug to a true value in BlackOilWellModelGeneric.
Then, the following debugging code can be added to e.g. one of
GasLiftSingleWell, GasLiftGroupState, or GasLiftStage2 :
auto count = debugUpdateGlobalCounter_();
if (count == some_integer) {
displayDebugMessage_("stop here");
}
Here, the integer "some_integer" is determined typically by looking at
the debugging output of a previous run. This can be done since the
call to debugUpdateGlobalCounter_() will print out the current value
of the counter and then increment the counter by one. And it will be
easy to recognize these values in the debug ouput. If you find a place
in the output that looks suspect, just take a note of the counter
value in the output around that point and insert the value for
"some_integer", then after recompiling the code with the desired value
for "some_integer", it is now easy to set a breakpoint in GDB at the
line
displayDebugMessage_("stop here").
shown in the above snippet. This should improve the ability to quickly
to set a breakpoint in GDB around at a given time and point in the simulation.