This commit adds a new flag data member,
wellStructureChangedDynamically_
to the generic black-oil well model. This flag captures the
well_structure_changed
value from the 'SimulatorUpdate' structure in the updateEclWells()
member function. Then, in BlackoilWellModel::beginTimeStep(), we
key a well structure update off this flag when set. This, in turn,
enables creating or opening wells as a result of an ACTIONX block
updating the structure in the middle of a report step.
This commit activates the support for calculating WBPn summary
result values per well in parallel. To affect the calculation we
add two new data members in BlackoilWellModelGeneric:
- conn_idx_map_:
Maps well's connection index (0..getConnections().size() - 1) to
connections on current rank. Its local() connections are
negative 1 (-1) if the connection is not on current rank, and a
non-negative value otherwise. The global() function maps well
connections on current rank to global connection ID for each
well. Effectively the reverse of local(). Finally, the open()
function maps well connections on current rank to open/flowing
connections on current rank. Negative 1 if connection is not
flowing.
- wbpCalculationService:
Parallel collection of WBPn calculation objects that knows how
to exchange source and result information between all ranks in a
communicator. Also handles distributed wells.
We furthermore need a way to compute connection-level fluid mixture
density values. For the standard well class we add a way to access
the StandardWellConnection's 'perf_densities_' values. However,
since these are defined for open/flowing connections only, this
means we're not able to fully meet the requirements of the
WELL/ALL
WPAVE depth correction procedure for standard wells. The
multi-segmented well type, on the other hand, uses the fluid mixture
density in the associated well segment and is therefore well defined
for ALL connections. OPEN well connections are supported for both
well types.
to handle the situation that a well can be `SHUT` in the Schedule.
If stored in PerfData, when a well is `SHUT`, the inforamtion related to
WINJMULT will be discarded.
Before we want to change how the `PerfData` works, storing
`inj_multiplier` in BlackoilWellModelGeneric is the viable approach.
without considering the iteration number. Because of the different
implementaion from other simulators, it is difficult to honour
procedure-dependent parameters.