The pvt interface is extened to handle wet gas
1. A function for rvSat is added to the interface
2. An interface that takes rv and the fluid condition as an input for
the gas properties is added. The old interface without rv and the fluid
condition is kept in the file.
3. The new interface is implemented in BlackoilPropsAd and
BlackoilPropsAdFromDeck.
A simulator that tests wet gas is not yet implemented.
I'm neither sure that this is fully correct nor that I found all
occurences (so far, the output writing code is missing in this patch),
but it seems to work for SPE1...
Commit 4aa0eaf introduced density and viscosity evaluators into the
BlackoilPropsAdInterface that accepted an externally assignable
condition to distinguish saturated from unsaturated cases. As a
result of a few low-level technical problems with that approach,
this commit changes those affected interfaces to use the black-oil
specific 'PhasePresence' facility of opm-core's commit a033329.
Update callers accordingly.
The criteria for whether the fluid is saturated or not is moved from the
within the pvt calculations to the solver, and passed to the pvt
calculations as a array of boolean values.
Notes:
- Interface was already present, just disabled.
- Class BlackoilPropsAd cannot properly implement rsMax() with derivatives,
and implements only a throw statement.
Specifically,
- #include <config.h> where appropriate (all .cpp files)
- Adjust include statements to account for sub-directory locations
of .hpp files.