opm-simulators/tests/run-vtu-test.sh
Andreas Lauser 0a5b63f70e test runner: allow an arbitrary number of reference results
if one of the files matches (fuzzyly, obviously), the test counts as
passed if none matches it counts as failed. this lets us add reference
results for hosts that need the same number of time steps, but for
whatever reason produce a different result. also, the number of time
steps required to produce the result do not matter anymore, as long as
the data is the same (in the fuzzy sense).
2013-01-11 18:16:29 +01:00

220 lines
6.7 KiB
Bash
Executable File

#! /bin/bash
#
# Runs a test from the test directory and compare the resulting VTU files.
#
# Usage:
#
# runTest.sh REFERENCE_RESULT_FILE TEST_RESULT_FILE TEST_BINARY TEST_ARGS
#
function usage() {
echo "Usage:"
echo
echo "runTest.sh TEST_TYPE TEST_BINARY [TEST_ARGS]"
echo "where TEST_TYPE can either be --plain or --simulation"
};
function validateResults() {
OUTPUT_FILE="$1"
SIM_NAME="$1"
for REFERENCE_RESULT in referencesolutions/$SIM_NAME*; do
if python bin/fuzzycomparevtu.py "$REFERENCE_RESULT" "$TEST_RESULT"; then
# SUCCESS!!!!!!
echo "Result file '$TEST_RESULT' and reference result '$REFERENCE_RESULT' are identical"
return 0
fi
done
echo "The files \"$TEST_RESULT\" and \"$REFERENCE_RESULT\" are different."
echo "Make sure the contents of \"$TEST_RESULT\" are still valid and "
echo "make it the reference result if necessary."
exit 1
}
TEST_TYPE="$1"
TEST_NAME="$2"
TEST_ARGS="${@:3:100}"
# make sure we have at least 2 parameters
if test "$#" -lt 2; then
echo "Wrong number of parameters"
echo
usage
exit 1
fi
# find the binary in the its folder
TEST_BINARY=$(find -type f -executable -name "$TEST_NAME")
# make sure the binary is of the test is present
if ! test -x "$TEST_BINARY"; then
echo "$TEST_NAME does not exist or is not executable"
echo
usage
exit 1
fi
#run the test
echo "######################"
echo "# Running test '$TEST_NAME'"
echo "######################"
case "$TEST_TYPE" in
"--simulation")
RND="$RANDOM"
"$TEST_BINARY" $TEST_ARGS | tee "test-$RND.log"
RET="${PIPESTATUS[0]}"
if test "$RET" != "0"; then
echo "Executing the binary failed!"
rm "test-$RND.log"
exit 1
fi
# compare the results
echo "######################"
echo "# Comparing results"
echo "######################"
SIM_NAME=$(grep "Initializing problem" test-$RND.log | sed "s/.*\"\(.*\)\".*/\1/" | head -n1)
NUM_TIMESTEPS=$(grep "Writing result" test-$RND.log | wc -l)
TEST_RESULT=$(printf "%s-%05i" $SIM_NAME $NUM_TIMESTEPS)
TEST_RESULT=$(ls $TEST_RESULT.*)
rm "test-$RND.log"
if ! test -r "$TEST_RESULT"; then
echo "File $TEST_RESULT does not exist or is not readable"
exit 1
fi
validateResults $TEST_RESULT $SIM_NAME
exit 0
;;
"--simulation-diffusion")
if ! "$TEST_BINARY" $TEST_ARGS ; then
echo "Executing the binary failed!"
exit 1
fi
if ! python bin/fuzzycomparevtu.py referencesolutions/mimeticdiffusion-00001.vtu mimeticdiffusion-00001.vtu; then
echo "The files \"mimeticdiffusion-00001.vtu\" and \"referencesolutions/mimeticdiffusion-00001.vtu\" are different."
echo "Make sure the contents of \"mimeticdiffusion-00001.vtu\" are still valid and "
echo "make it the reference result if necessary."
exit 1
fi
exit 0
;;
"--parallel-simulation")
RND="$RANDOM"
mpirun -np 4 "$TEST_BINARY" $TEST_ARGS | tee "test-$RND.log"
RET="${PIPESTATUS[0]}"
if test "$RET" != "0"; then
echo "Executing the binary failed!"
rm "test-$RND.log"
exit 1
fi
rm "test-$RND.log"
# # compare the results
# echo "######################"
# echo "# Comparing results"
# echo "######################"
# SIM_NAME=$(grep "Writing result file for" test-$RND.log | sed "s/.*\"\(.*\)\".*/\1/" | head -n1)
# TEST_RESULT=$(ls $SIM_NAME*.vtu $SIM_NAME*.vtp 2> /dev/null | sort | tail -n 1)
# rm "test-$RND.log"
# if ! test -r "$TEST_RESULT"; then
# echo "File $TEST_RESULT does not exist or is not readable"
# exit 1
# fi
# REFERENCE_RESULT="referencesolutions/$TEST_RESULT"
# if ! test -r "$REFERENCE_RESULT"; then
# echo "File $REFERENCE_RESULT does not exist or is not readable"
# exit 1
# fi
# if ! python bin/fuzzycomparevtu.py "$REFERENCE_RESULT" "$TEST_RESULT"; then
# echo "The files \"$TEST_RESULT\" and \"$REFERENCE_RESULT\" are different."
# echo "Make sure the contents of \"$TEST_RESULT\" are still valid and "
# echo "make it the reference result if necessary."
# exit 1
# fi
# # SUCCESS!!!!!!
# echo "Result and reference result are identical"
exit 0
;;
"--restart")
RND="$RANDOM"
"$TEST_BINARY" $TEST_ARGS | tee "test-$RND.log"
RET="${PIPESTATUS[0]}"
if test "$RET" != "0"; then
echo "Executing the binary failed!"
rm "test-$RND.log"
exit 1
fi
RESTART_TIME=$(grep "Serialize" "test-$RND.log" | tail -n 1 | sed "s/.*time=\([0-9.e+\-]*\).*/\1/")
rm "test-$RND.log"
if ! "$TEST_BINARY" $TEST_ARGS --restart-time="$RESTART_TIME"; then
echo "Restarting $TEST_BINARY failed"
exit 1;
fi
exit 0
;;
"--parameters")
HELP_MSG="$($TEST_BINARY --help)"
if test "$(echo $HELP_MSG | grep -i usage)" == ''; then
echo "$TEST_BINARY did not accept '--help' parameter"
exit 1
fi
HELP_MSG2="$($TEST_BINARY -h)"
if test "$HELP_MSG" != "$HELP_MSG2"; then
echo "Output of $TEST_BINARY different when passing '--help' and '-h'"
exit 1
fi
RND="$RANDOM"
cat > "paramfile-$RND.ini" <<EOF
EndTime=100
InitialTimeStepSize=100
UndefinedParam="blubb"
EOF
if ! $TEST_BINARY --parameter-file="paramfile-$RND.ini" > /dev/null; then
echo "$TEST_BINARY does not correctly read a parameter file"
exit 1
elif $TEST_BINARY --parameter-file="foobar.ini" > /dev/null; then
echo "$TEST_BINARY does not abort even though the specified parameter file does not exist"
exit 1
elif ! $TEST_BINARY --foo --end-time=1 > /dev/null; then
echo "$TEST_BINARY des not accept a flag parameters"
exit 1
fi
# test some invalid parameter names
for PARAM in foo -- -0foo --0foo --foo--bar --foo- -foo --foo-bar§=abc ; do
if $TEST_BINARY "$PARAM" --end-time=100 > /dev/null; then
echo "$TEST_BINARY accepted invalid command line option '$PARAM'"
exit 1
fi
done
echo "Test successful"
exit 0
;;
"--plain")
if ! "$TEST_BINARY" $TEST_ARGS; then
exit 1
fi
exit 0
;;
esac