-- Most of the following sections are not actually needed by the test,
-- but it is required by the Eclipse reference manual that they are
-- present. Also, the higher level opm-parser classes
-- (i.e. Opm::EclipseState et al.) assume that they are present.
-------------------------------------
RUNSPEC
WATER
OIL
GAS
DIMENS
1 1 20 /
TABDIMS
1 1 40 20 1 20 /
EQLDIMS
-- NTEQUL
1 /
-------------------------------------
GRID
-- Opm::EclipseState assumes that _some_ grid gets defined, so let's
-- specify a fake one...
DXV
1*1 /
DYV
1*1 /
DZV
20*5 /
DEPTHZ
4*0.0 /
PORO
20*0.3 /
PERMX
20*500 /
-------------------------------------
PROPS
PVDO
100 1.0 1.0
200 0.9 1.0
/
PVDG
100 0.010 0.1
200 0.005 0.2
/
PVTW
1.0 1.0 4.0E-5 0.96 0.0
/
SWOF
0.2 0 1 0.4
1 1 0 0.1
/
SGOF
0 0 1 0.2
0.8 1 0 0.5
/
DENSITY
700 1000 1
/
-------------------------------------
SOLUTION
EQUIL
50 150 50 0.25 20 0.35 1* 1* 0
/
-------------------------------------
SCHEDULE
-- empty section