opm-simulators/tests/capillary.DATA
Atgeirr Flø Rasmussen 3d27454c6b Make grid in deck have larger number of cells.
This makes some tests succeed that use this deck only
for its properties and not its grid: if the grid in the
deck has fewer cells than the grid that is used for the
test we will fail in the SATNUM mapping.
2015-10-01 15:20:08 +02:00

82 lines
992 B
Plaintext

-- Most of the following sections are not actually needed by the test,
-- but it is required by the Eclipse reference manual that they are
-- present. Also, the higher level opm-parser classes
-- (i.e. Opm::EclipseState et al.) assume that they are present.
-------------------------------------
RUNSPEC
WATER
OIL
GAS
DIMENS
40 40 40 /
TABDIMS
1 1 40 20 1 20 /
EQLDIMS
-- NTEQUL
1 /
-------------------------------------
GRID
-- Opm::EclipseState assumes that _some_ grid gets defined, so let's
-- specify a fake one...
DXV
40*1 /
DYV
40*1 /
DZV
40*1 /
DEPTHZ
1681*123.456 /
-------------------------------------
PROPS
PVDO
100 1.0 1.0
200 0.9 1.0
/
PVDG
100 0.010 0.1
200 0.005 0.2
/
PVTW
1.0 1.0 4.0E-5 0.96 0.0
/
SWOF
0.2 0 1 0.4
1 1 0 0.1
/
SGOF
0 0 1 0.2
0.8 1 0 0.5
/
DENSITY
700 1000 1
/
-------------------------------------
SOLUTION
EQUIL
50 150 50 0.25 20 0.35 1* 1* 0
/
-------------------------------------
SCHEDULE
-- empty section