opm-simulators/opm
Bård Skaflestad 86550fd6c9 effectiveRadius: Fix numerator formula
We must take the square root of the permeability ratios, not use them
as is.  This was lost in the refactorisation commit 96cf137.

Pointy hat: @bska.
2014-09-02 15:12:50 +02:00
..
core effectiveRadius: Fix numerator formula 2014-09-02 15:12:50 +02:00