mirror of
https://github.com/OPM/opm-simulators.git
synced 2024-12-26 09:10:59 -06:00
8810fa65af
Introduces two new data types BasicRates and LimitedRates to capture oil, gas, and water rates, and whether they have been limited by well or group targets. This reduces the number of variables that are passed to and returned from various methods and thus makes the code easier to read.
179 lines
6.4 KiB
C++
179 lines
6.4 KiB
C++
/*
|
|
Copyright 2020 Equinor ASA.
|
|
|
|
This file is part of the Open Porous Media project (OPM).
|
|
|
|
OPM is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
OPM is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with OPM. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
namespace Opm {
|
|
|
|
template<typename TypeTag>
|
|
GasLiftSingleWell<TypeTag>::
|
|
GasLiftSingleWell(const StdWell &std_well,
|
|
const Simulator &ebos_simulator,
|
|
const SummaryState &summary_state,
|
|
DeferredLogger &deferred_logger,
|
|
WellState &well_state,
|
|
const GroupState &group_state,
|
|
GasLiftGroupInfo &group_info,
|
|
GLiftSyncGroups &sync_groups,
|
|
bool glift_debug
|
|
)
|
|
// The parent class GasLiftSingleWellGeneric contains all stuff
|
|
// that is not dependent on TypeTag
|
|
: GasLiftSingleWellGeneric(
|
|
deferred_logger,
|
|
well_state,
|
|
group_state,
|
|
std_well.wellEcl(),
|
|
summary_state,
|
|
group_info,
|
|
ebos_simulator.vanguard().schedule(),
|
|
ebos_simulator.episodeIndex(),
|
|
sync_groups,
|
|
glift_debug
|
|
)
|
|
, ebos_simulator_{ebos_simulator}
|
|
, std_well_{std_well}
|
|
{
|
|
const auto& gl_well = *gl_well_;
|
|
if(useFixedAlq_(gl_well)) {
|
|
updateWellStateAlqFixedValue_(gl_well);
|
|
this->optimize_ = false; // lift gas supply is fixed
|
|
}
|
|
else {
|
|
setAlqMaxRate_(gl_well);
|
|
this->optimize_ = true;
|
|
}
|
|
|
|
const auto& pu = std_well_.phaseUsage();
|
|
this->oil_pos_ = pu.phase_pos[Oil];
|
|
this->gas_pos_ = pu.phase_pos[Gas];
|
|
this->water_pos_ = pu.phase_pos[Water];
|
|
// get the alq value used for this well for the previous iteration (a
|
|
// nonlinear iteration in assemble() in BlackoilWellModel).
|
|
// If gas lift optimization has not been applied to this well yet, the
|
|
// default value is used.
|
|
this->orig_alq_ = this->well_state_.getALQ(this->well_name_);
|
|
if(this->optimize_) {
|
|
setAlqMinRate_(gl_well);
|
|
// NOTE: According to item 4 in WLIFTOPT, this value does not
|
|
// have to be positive.
|
|
// TODO: Does it make sense to have a negative value?
|
|
this->alpha_w_ = gl_well.weight_factor();
|
|
if (this->alpha_w_ <= 0 ) {
|
|
displayWarning_("Nonpositive value for alpha_w ignored");
|
|
this->alpha_w_ = 1.0;
|
|
}
|
|
|
|
// NOTE: According to item 6 in WLIFTOPT:
|
|
// "If this value is greater than zero, the incremental gas rate will influence
|
|
// the calculation of the incremental gradient and may be used
|
|
// to discourage the allocation of lift gas to wells which produce more gas."
|
|
// TODO: Does this mean that we should ignore this value if it
|
|
// is negative?
|
|
this->alpha_g_ = gl_well.inc_weight_factor();
|
|
|
|
// TODO: adhoc value.. Should we keep max_iterations_ as a safety measure
|
|
// or does it not make sense to have it?
|
|
this->max_iterations_ = 1000;
|
|
}
|
|
}
|
|
|
|
/****************************************
|
|
* Private methods in alphabetical order
|
|
****************************************/
|
|
|
|
template<typename TypeTag>
|
|
GasLiftSingleWellGeneric::BasicRates
|
|
GasLiftSingleWell<TypeTag>::
|
|
computeWellRates_( double bhp, bool bhp_is_limited, bool debug_output ) const
|
|
{
|
|
std::vector<double> potentials(this->num_phases_, 0.0);
|
|
this->std_well_.computeWellRatesWithBhp(
|
|
this->ebos_simulator_, bhp, potentials, this->deferred_logger_);
|
|
if (debug_output) {
|
|
const std::string msg = fmt::format("computed well potentials given bhp {}, "
|
|
"oil: {}, gas: {}, water: {}", bhp,
|
|
-potentials[this->oil_pos_], -potentials[this->gas_pos_],
|
|
-potentials[this->water_pos_]);
|
|
displayDebugMessage_(msg);
|
|
}
|
|
|
|
for (auto& potential : potentials) {
|
|
potential = std::min(0.0, potential);
|
|
}
|
|
return {-potentials[this->oil_pos_],
|
|
-potentials[this->gas_pos_],
|
|
-potentials[this->water_pos_],
|
|
bhp_is_limited
|
|
};
|
|
}
|
|
|
|
template<typename TypeTag>
|
|
std::optional<double>
|
|
GasLiftSingleWell<TypeTag>::
|
|
computeBhpAtThpLimit_(double alq) const
|
|
{
|
|
auto bhp_at_thp_limit = this->std_well_.computeBhpAtThpLimitProdWithAlq(
|
|
this->ebos_simulator_,
|
|
this->summary_state_,
|
|
this->deferred_logger_,
|
|
alq);
|
|
if (bhp_at_thp_limit) {
|
|
if (*bhp_at_thp_limit < this->controls_.bhp_limit) {
|
|
const std::string msg = fmt::format(
|
|
"Computed bhp ({}) from thp limit is below bhp limit ({}), (ALQ = {})."
|
|
" Using bhp limit instead",
|
|
*bhp_at_thp_limit, this->controls_.bhp_limit, alq);
|
|
displayDebugMessage_(msg);
|
|
bhp_at_thp_limit = this->controls_.bhp_limit;
|
|
}
|
|
//bhp_at_thp_limit = std::max(*bhp_at_thp_limit, this->controls_.bhp_limit);
|
|
}
|
|
else {
|
|
const std::string msg = fmt::format(
|
|
"Failed in getting converged bhp potential from thp limit (ALQ = {})", alq);
|
|
displayDebugMessage_(msg);
|
|
}
|
|
return bhp_at_thp_limit;
|
|
}
|
|
|
|
template<typename TypeTag>
|
|
void
|
|
GasLiftSingleWell<TypeTag>::
|
|
setAlqMaxRate_(const GasLiftOpt::Well &well)
|
|
{
|
|
auto& max_alq_optional = well.max_rate();
|
|
if (max_alq_optional) {
|
|
// NOTE: To prevent extrapolation of the VFP tables, any value
|
|
// entered here must not exceed the largest ALQ value in the well's VFP table.
|
|
this->max_alq_ = *max_alq_optional;
|
|
}
|
|
else { // i.e. WLIFTOPT, item 3 has been defaulted
|
|
// According to the manual for WLIFTOPT, item 3:
|
|
// The default value should be set to the largest ALQ
|
|
// value in the well's VFP table
|
|
const auto& table = std_well_.vfp_properties_->getProd()->getTable(
|
|
this->controls_.vfp_table_number);
|
|
const auto& alq_values = table.getALQAxis();
|
|
// Assume the alq_values are sorted in ascending order, so
|
|
// the last item should be the largest value:
|
|
this->max_alq_ = alq_values.back();
|
|
}
|
|
}
|
|
|
|
}
|