mirror of
https://github.com/OPM/opm-simulators.git
synced 2025-02-25 18:55:30 -06:00
before this, gradients had the direction of the face between two finite volumes, now they exhibit the direction of the two FV-centers. For axis-aligned grids the result is identical for interior faces, but it is different for boundary faces or if faces are not axis-aligned. This patch fixes the SPE9 troubles with anisotropic permeabilities on tilted grids...