opm-simulators/parallelTests.cmake
Kai Bao cacec2739c moving the inj_multiplier to BlackoilWellModelGeneric
to handle the situation that a well can be `SHUT` in the Schedule.

If stored in PerfData, when a well is `SHUT`, the inforamtion related to
WINJMULT will be discarded.

Before we want to change how the `PerfData` works, storing
`inj_multiplier` in BlackoilWellModelGeneric is the viable approach.
2023-06-27 12:49:25 +02:00

199 lines
11 KiB
CMake

opm_set_test_driver(${PROJECT_SOURCE_DIR}/tests/run-parallel-regressionTest.sh "")
# Different tolerances for these tests
set(abs_tol_parallel 0.02)
set(rel_tol_parallel 8e-5)
set(coarse_rel_tol_parallel 1e-2)
add_test_compare_parallel_simulation(CASENAME spe1
FILENAME SPE1CASE2
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${rel_tol_parallel}
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8 --ecl-enable-drift-compensation=false)
add_test_compare_parallel_simulation(CASENAME spe1_gaswater
FILENAME SPE1CASE2_GASWATER
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${rel_tol_parallel}
DIR spe1
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8)
add_test_compare_parallel_simulation(CASENAME spe9
FILENAME SPE9_CP_SHORT
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${rel_tol_parallel}
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8 --ecl-enable-drift-compensation=false)
# A test for distributed standard wells. We load distribute only along the z-axis
add_test_compare_parallel_simulation(CASENAME spe9_dist_z
FILENAME SPE9_CP_SHORT
DIR spe9
SIMULATOR flow_distribute_z
ABS_TOL ${abs_tol_parallel}
REL_TOL ${rel_tol_parallel}
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8 --ecl-enable-drift-compensation=false)
add_test_compare_parallel_simulation(CASENAME spe9group
FILENAME SPE9_CP_GROUP
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${coarse_rel_tol_parallel}
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8)
add_test_compare_parallel_simulation(CASENAME spe3
FILENAME SPE3CASE1
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${coarse_rel_tol_parallel}
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8 --tolerance-wells=1e-7)
add_test_compare_parallel_simulation(CASENAME spe1_solvent
FILENAME SPE1CASE2_SOLVENT
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${coarse_rel_tol_parallel}
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8)
add_test_compare_parallel_simulation(CASENAME polymer_simple2D
FILENAME 2D_THREEPHASE_POLY_HETER
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${coarse_rel_tol}
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8)
add_test_compare_parallel_simulation(CASENAME spe1_foam
FILENAME SPE1FOAM
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${coarse_rel_tol_parallel})
add_test_compare_parallel_simulation(CASENAME spe1_thermal
FILENAME SPE1CASE2_THERMAL
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${coarse_rel_tol_parallel}}
DIR spe1
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8)
add_test_compare_parallel_simulation(CASENAME spe1_thermal_onephase
FILENAME SPE1CASE2_THERMAL_ONEPHASE
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${rel_tol}
DIR spe1
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8)
add_test_compare_parallel_simulation(CASENAME spe1_water
FILENAME SPE1CASE1_WATER
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${rel_tol}
DIR spe1
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8 --tolerance-wells=1e-7)
add_test_compare_parallel_simulation(CASENAME spe1_brine
FILENAME SPE1CASE1_BRINE
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${coarse_rel_tol_parallel}
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-6)
add_test_compare_parallel_simulation(CASENAME fetkovich_2d
FILENAME 2D_FETKOVICHAQUIFER
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${rel_tol_parallel}
DIR aquifer-fetkovich
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-6)
add_test_compare_parallel_simulation(CASENAME ctaquifer_2d_oilwater
FILENAME 2D_OW_CTAQUIFER
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${rel_tol_parallel}
DIR aquifer-oilwater
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-6)
add_test_compare_parallel_simulation(CASENAME 3d_tran_operator
FILENAME 3D_TRAN_OPERATOR
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${rel_tol_parallel}
DIR parallel_fieldprops
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-6)
add_test_compare_parallel_simulation(CASENAME numerical_aquifer_3d_2aqu
FILENAME 3D_2AQU_NUM
SIMULATOR flow
ABS_TOL 0.17
REL_TOL ${coarse_rel_tol_parallel}
DIR aquifer-num
TEST_ARGS --tolerance-cnv=0.000003 --time-step-control=pid --linear-solver=cpr_trueimpes)
add_test_compare_parallel_simulation(CASENAME aquflux_01
FILENAME AQUFLUX-01
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${coarse_rel_tol_parallel}
DIR aquifers
TEST_ARGS --enable-tuning=true)
add_test_compare_parallel_simulation(CASENAME aquflux_02
FILENAME AQUFLUX-02
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${coarse_rel_tol_parallel}
DIR aquifers
TEST_ARGS --enable-tuning=true)
add_test_compare_parallel_simulation(CASENAME network_balance_01
FILENAME NETWORK-01
SIMULATOR flow
ABS_TOL 0.04
REL_TOL 0.02
DIR network
TEST_ARGS --enable-tuning=true)
add_test_compare_parallel_simulation(CASENAME numerical_aquifer_3d_1aqu
FILENAME 3D_1AQU_3CELLS
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${coarse_rel_tol_parallel}
DIR aquifer-num
TEST_ARGS --tolerance-cnv=0.00003 --time-step-control=pid --linear-solver=cpr_trueimpes)
add_test_compare_parallel_simulation(CASENAME actionx_m1
FILENAME ACTIONX_M1
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${coarse_rel_tol_parallel}
DIR udq_actionx
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-6)
add_test_compare_parallel_simulation(CASENAME winjmult_msw
FILENAME WINJMULT_MSW
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL 0.12
DIR winjmult
TEST_ARGS --enable-tuning=true)
add_test_compare_parallel_simulation(CASENAME 3_a_mpi_multflt_mod2
FILENAME 3_A_MPI_MULTFLT_SCHED_MODEL2
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL ${rel_tol_parallel}
DIR model2
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8 --ecl-enable-drift-compensation=false)
add_test_compare_parallel_simulation(CASENAME rxft
FILENAME TEST_RXFT
SIMULATOR flow
ABS_TOL ${abs_tol_parallel}
REL_TOL 1.0e-3
DIR rxft_smry
TEST_ARGS --linear-solver-reduction=1e-7 --tolerance-cnv=5e-6 --tolerance-mb=1e-8 --ecl-enable-drift-compensation=false)