The test check that the rates are set to zero for stopped wells.
59 lines
501 B
Plaintext
59 lines
501 B
Plaintext
RUNSPEC
|
|
|
|
OIL
|
|
GAS
|
|
WATER
|
|
|
|
|
|
DIMENS
|
|
10 10 1 /
|
|
|
|
GRID
|
|
|
|
DXV
|
|
10*1000.0
|
|
/
|
|
|
|
DYV
|
|
10*1000.0
|
|
/
|
|
|
|
DZ
|
|
100*20.0
|
|
/
|
|
|
|
TOPS
|
|
100*10
|
|
/
|
|
|
|
|
|
SCHEDULE
|
|
|
|
WELSPECS
|
|
'INJ1' 'G' 1 1 8335 'GAS' /
|
|
'PROD1' 'G' 10 10 8400 'OIL' /
|
|
/
|
|
|
|
COMPDAT
|
|
'INJ1' 1 1 1 1 'OPEN' 1 10.6092 0.5 /
|
|
'PROD1' 10 1 1 1 'OPEN' 0 10.6092 0.5 /
|
|
/
|
|
|
|
WCONPROD
|
|
'PROD1' 'OPEN' 'ORAT' 20000 4* 1000 /
|
|
/
|
|
|
|
WCONINJE
|
|
'INJ1' 'GAS' 'OPEN' 'RATE' 100 200 400 /
|
|
/
|
|
|
|
|
|
TSTEP
|
|
1 /
|
|
|
|
WELOPEN
|
|
'INJ1' 'STOP' 5* /
|
|
/
|
|
|
|