mirror of
https://github.com/OPM/opm-simulators.git
synced 2024-12-18 21:43:27 -06:00
e1d2fa2088
- Saturations, phase pressures, and standard initialsation of RS and RV now agree to baseline. - Tables of RS and RV versus vertical depth (kw RSVD RVVD) have been hardcoded for testing (need new parser) and the calculations agree to baseline in the gas and oil zones. In the water zone there is some differences: Our code computes saturated RS and RV using the final phase pressures (these are modified to be consistent with saturations and capillary pressures) while the baseline uses unmodified phase pressures. |
||
---|---|---|
.. | ||
core |