Updates Grafana Alertmanager to work with new interface from grafana/alerting#161. This change stops passing user-defined templates to the Grafana Alertmanager by persisting them to disk and instead passes them by string.
Previously receivers were only validated before saving the alertmanager
configuration. This is a suboptimal experience for those upgrading with preview
as the failed channel upgrade will return an API error instead of being
summarized in the table.
Adds a feature flag (alertingUpgradeDryrunOnStart) that will dry-run the legacy
alert upgrade on startup. It is enabled by default.
When on legacy alerting, this feature flag will log the results of the legacy
alerting upgrade on startup and draw attention to anything in the current legacy
alerting configuration that will cause issues when the upgrade is eventually
performed. It acts as a log warning for those where action is required before
upgrading to Grafana v11 where legacy alerting will be removed.
If the db already has an entry in the kvstore for the silences of an
alertmanager before the migration has taken place, then it's possible that the
active alertmanager will overwrite the silence file created by the migration
before it has a chance to load it into memory.
This should not happen normally but is possible in edge-cases.
This change opts to bypass the unnecessary step of writing the silences to disk
during the migration and instead write them directly to the kvstore. This avoids
the race condition entirely and is more correct as we treat the database as the
source of truth for AM state.
Alerting: Remove start page of upgrade preview
Alerting upgrade page will now always show the summary table even before
upgrading any alerts or notification channels. There a few reasons for this:
- The information on the start page is redundant as it's now contained in the
documentation.
- Previously, if some unexpected issue prevented performing a full upgrade, a
user would have limited to no means to using the preview tool to help fix the
problem. This is because you could not see the summary table until the full
upgrade was performed at least once. Now, you can upgrade individual alerts and
notification channels from the beginning.
* Alerting: upgrade preview enable folder alert tab and dashboard alert panel
Enable the folder alert tab and the dashboard alert panel when the
alertingPreviewUpgrade feature flag is enabled
* Link directly to folder alerts in upgrade page
AM config applied via API would use the PostableUserConfig as the AM raw
config and also the hash used to decide when the AM config has changed.
However, when applied via the periodic sync the PostableApiAlertingConfig would
be used instead.
This leads to two issues:
- Inconsistent hash comparisons when modifying the AM causing redundant applies.
- GetStatus assumed the raw config was PostableUserConfig causing the endpoint
to return correctly after a new config is applied via API and then nothing once
the periodic sync runs.
Note: Technically, the upstream GrafanaAlertamanger GetStatus shouldn't be
returning PostableUserConfig or PostableApiAlertingConfig, but instead
GettableStatus. However, this issue required changes elsewhere and is out of
scope.
Fixes the group by custom labels and timings override logic in the simplified routing section of the edit rule page.
Previously:
- Custom labels would fail on first attempt at adding them to the group by.
- Timings fields required all timings to be overridden instead of any of them.
* Alerting: Add action, scope, role_id to permission table
The existing role_id, action, scope index has the wrong ordering to be most
effectively used in dashboard/folder permission requests.
On a large tests set, the slow database calls were on the order of ~30-40ms, so
when performed individually they don't have that large of a latency impact.
However, when done in bulk in the migration this adds up to some very slow
requests.
After the index is added these same database calls are reduced to ~4-5ms
* Change index to action, scope, role_id
* Make new index unique and drop [role_id, action, scope] index
* Alerting: During legacy migration reduce the number of created silences
During legacy migration every migrated rule was given a label rule_uid=<uid>.
This was used to silence DatasourceError/DatasourceNoData alerts for
migrated rules that had either ExecutionErrorState/NoDataState set to
keep_state, respectively.
This could potentially create a large amount of silences and a high cardinality
label. Both of these scenarios have poor outcomes for CPU load and latency in
unified alerting.
Instead, this change creates one label per ExecutionErrorState/NoDataState when
they are set to keep_state as well as two silence rules, if rules with said
labels were created during migration. These silence rules are:
- __legacy_silence_error_keep_state__ = true
- __legacy_silence_nodata_keep_state__ = true
This will drastically reduce the number of created silence rules in most cases
as well as not create the potentially high cardinality label `rule_uid`.
When using the legacy migration dry-run, if a cancel takes a long time (long
enough for the page to poll) the page will incorrectly render the previous
data.
This change stops the polling while the upgrading or cancelling.
* Alerting: Increase size of kvstore value type for MySQL to LONGTEXT
alertmanager uses the kvstore to persist its notification log and the current
column limit for MySQL (16.7mb) puts the maximum entries at a level that is
potentially achievable for heavy alerting users (~40-80k entries).
In comparison, the current type for PSQL (TEXT) is effectively unlimited and
I believe SQLIte defaults to 2gb which is also plenty of leeway.
* Alerting: Create feature flag for alert query optimization
Adds a feature flag alertingQueryOptimization for an already existing
functionality: alert query optimization. This feature flag will now be disabled
by default.
* Alerting: Fix NoData & Error alerts not resolving when rule is reset
On rule reset, when creating the PostableAlerts StateToPostableAlert did not
attach the correct NoData/Error alertname and rulename labels to expire/resolve
the active alerts when the previous cached state was NoData/Error.
This PR has two steps that together create a functional dry-run capability for the migration.
By enabling the feature flag alertingPreviewUpgrade when on legacy alerting it will:
a. Allow all Grafana Alerting background services except for the scheduler to start (multiorg alertmanager, state manager, routes, …).
b. Allow the UI to show Grafana Alerting pages alongside legacy ones (with appropriate in-app warnings that UA is not actually running).
c. Show a new “Alerting Upgrade” page and register associated /api/v1/upgrade endpoints that will allow the user to upgrade their organization live without restart and present a summary of the upgrade in a table.
Some refactoring that will simplify next changes for dry-run PRs. This should be no-op as far as the created ngalert resources and database state, though it does change some logs.
The key change here is to modify migrateOrg to return pairs of legacy struct + ngalert struct instead of actually persisting the alerts and alertmanager config. This will allow us to capture error information during dry-run migration.
It also moves most persistence-related operations such as title deduplication and folder creation to the right before we persist. This will simplify eventual partial migrations (individual alerts, dashboards, channels, ...).
Additionally it changes channel code to deal with PostableGrafanaReceiver instead of PostableApiReceiver (integration instead of contact point).
* Separate overlapping legacy and UA alerting routes
api/alert-notifiers, alerting/list, and alerting/notifications existed in both
legacy and UA.
Rename legacy route paths and nav ids to be independent of UA ones.
* In migration, create one label per channel
This PR changes how routing is done by the legacy alerting migration.
Previously, we created a single label on each alert rule that contained an array of contact point names. Ex: __contact__="slack legacy testing","slack legacy testing2"
This label was then routed against a series of regex-matching policies with continue=true. Ex: __contacts__ =~ .*"slack legacy testing".*
In the case of many contact points, this array could quickly become difficult to manage and difficult to grok at-a-glance.
This PR replaces the single __contact__ label with multiple __legacy_c_{contactname}__ labels and simple equality-matching policies. These channel-specific policies are nested in a single route under the top-level route which matches against __legacy_use_channels__ = true for ease of organization.
This should improve the experience for users wanting to keep the default migrated routing strategy but who also want to modify which contact points an alert sends to.
* Alerting: Add clean_upgrade config and deprecate force_migration
Upgrading to UA and rolling back will no longer delete any data by default.
Instead, each set of tables will remain unchanged when switching between
legacy and UA. As such, the force_migration config has been deprecated
and no extra configuration is required to roll back to legacy anymore.
If clean_upgrade is set to true when upgrading from legacy alerting to Unified
Alerting, grafana will first delete all existing Unified Alerting resources,
thus re-upgrading all organizations from scratch. If false or unset,
organizations that have previously upgraded will not lose their existing Unified
Alerting data when switching between legacy and Unified Alerting.
Similar to force_migration, it should be kept false when not needed as it may
cause unintended data-loss if left enabled.
---------
Co-authored-by: Christopher Moyer <35463610+chri2547@users.noreply.github.com>
* Alerting: Keep track of individual org migration status
Save migration status per migrated org.
Change the meaning (and key/value) of the org_id=0 entry
to store the current (previous) config value used by alerting.
This is so we can know when to upgrade/downgrade by
comparing with the new config value in
UnifiedAlerting.IsEnabled.
* Alerting: In migration improve deduplication of title and group
This change improves alert titles generated in the legacy migration
that occur when we need to deduplicate titles. Now when duplicate
titles are detected we will first attempt to append a sequential index,
falling back to a random uid if none are unique within 10 attempts.
This should cause shorter and more easily readable deduplicated
titles in most cases.
In addition, groups are no longer deduplicated. Instead we set them
to a combination of truncated dashboard name and humanized alert
frequency. This way, alerts from the same dashboard share a group
if they have the same evaluation interval. In the event that truncation
causes overlap, it won't be a big issue as all alerts will still be in a
group with the correct evaluation interval.
* Alerting: Apply query optimization to eval endpoints
Previously, query optimization was applied to alert queries when scheduled but
not when ran through `api/v1/eval` or `/api/v1/rule/test/grafana`. This could
lead to discrepancies between preview and scheduled alert results.
* Alerting: In migration, fallback to '1s' for malformed min interval
During legacy migration, when we encounter an alert datasource query
with a min interval (interval field in the query model) that is not
parseable, instead of failing the migration we fallback to a min interval
of 1s and continue.
The reason for this is a bug in legacy alerting (existing for a few major
versions) which allows arbitrary dashboard variables to be used as the
min interval, even though those variables do not work and will cause
the legacy alert to fail with `interval calculation failed: time: invalid
duration`.
* Alerting: Move migration from background service run to ngalert init
sqlite database write contention between the migration's single transaction and
dashboard provisioning's frequent commits was causing the migration to
fail with SQLITE_BUSY/SQLITE_BUSY_SNAPSHOT on all retries.
This is not a new issue for sqlite+grafana, but the discrepancy between the
length of the transactions was causing it to be very consistent. In addition,
since a failed migration has implications on the assumed correctness of the
alertmanager and alert rule definition state, we cause a server shutdown on
error. This can make e2e tests as well as some high-load provisioned
sqlite installations flaky on startup.
The correct fix for this is better transaction management across various
services and is out of scope for this change as we're primarily interested in
mitigating the current bout of server failures in e2e tests when using sqlite.
Reduce flakiness of e2e tests caused by write contention in sqlite
Write contention in sqlite on startup intermittently causes failed tests because
of failed service runs. This can have various root causes, one example is
dashboard provisioning:
Dashboard provisioning's frequent commits can cause other read transaction
snapshots to invalidate and throw SQLITE_BUSY/SQLITE_BUSY_SNAPSHOT. If those
failing transactions have a long length but not long enough to ensure all of
the dashboards have finished provisioning it will run out of retries and fail
entirely.
This change helps indirectly reduce these write contentions by limiting the
connection pool for e2e tests.
As a bonus, having our e2e tests run using `max_open_conn = 2` means it acts
as a guard against regressions that would affect certain internal instances
that run with these settings.
* Fix migration of custom dashboard permissions
Dashboard alert permissions were determined by both its dashboard and
folder scoped permissions, while UA alert rules only have folder
scoped permissions.
This means, when migrating an alert, we'll need to decide if the parent folder
is a correct location for the newly created alert rule so that users, teams,
and org roles have the same access to it as they did in legacy.
To do this, we translate both the folder and dashboard resource
permissions to two sets of SetResourcePermissionCommands. Each of these
encapsulates a mapping of all:
OrgRoles -> Viewer/Editor/Admin
Teams -> Viewer/Editor/Admin
Users -> Viewer/Editor/Admin
When the dashboard permissions (including those inherited from the parent
folder) differ from the parent folder permissions alone, we need to create a
new folder to represent the access-level of the legacy dashboard.
Compromises:
When determining the SetResourcePermissionCommands we only take into account
managed and basic roles. Fixed and custom roles introduce significant complexity
and synchronicity hurdles. Instead, we log a warning they had the potential to
override the newly created folder permissions.
Also, we don't attempt to reconcile datasource permissions that were
not necessary in legacy alerting. Users without access to the necessary
datasources to edit an alert rule will need to obtain said access separate from
the migration.
This PR replaces the vendored models in the migration with their equivalent ngalert models. It also replaces the raw SQL selects and inserts with service calls.
It also fills in some gaps in the testing suite around:
- Migration of alert rules: verifying that the actual data model (queries, conditions) are correct 9a7cfa9
- Secure settings migration: verifying that secure fields remain encrypted for all available notifiers and certain fields migrate from plain text to encrypted secure settings correctly e7d3993
Replacing the checks for custom dashboard ACLs will be replaced in a separate targeted PR as it will be complex enough alone.
* Alerting: Fix contact point testing with secure settings
Fixes double encryption of secure settings during contact point testing and removes code duplication
that helped cause the drift between alertmanager and test endpoint. Also adds integration tests to cover
the regression.
Note: provisioningStore is created to remove cycle and the unnecessary dependency.
This features adds a configuration option when creating an alert rule query. This option already exists as part of the alert query model but is not currently configurable through the UI.
* Alerting: No longer silence paused alerts during legacy migration
Now that we migrate paused legacy alerts to paused UA alert rules, we no longer need to silence them.
* Alerting: Make ApplyAlertmanagerConfiguration only decrypt/encrypt new/changed secure settings
Previously, ApplyAlertmanagerConfiguration would decrypt and re-encrypt all secure settings. However, this caused re-encrypted secure settings to be included in the raw configuration when applied to the embedded alertmanager, resulting in changes to the hash. Consequently, even if no actual modifications were made, saving any alertmanager configuration triggered an apply/restart and created a new historical entry in the database.
To address the issue, this modifies ApplyAlertmanagerConfiguration, which is called by POST `api/alertmanager/grafana/config/api/v1/alerts`, to decrypt and re-encrypt only new and updated secure settings. Unchanged secure settings are loaded directly from the database without alteration.
We determine whether secure settings have changed based on the following (already in-use) assumption: Only new or updated secure settings are provided via the POST `api/alertmanager/grafana/config/api/v1/alerts` request, while existing unchanged settings are omitted.
* Ensure saving a grafana-managed contact point will only send new/changed secure settings
Previously, when saving a grafana-managed contact point, empty string values were transmitted for all unset secure settings. This led to potential backend issues, as it assumed that only newly added or updated secure settings would be provided.
To address this, we now exclude empty ('', null, undefined) secure settings, unless there was a pre-existing entry in secureFields for that specific setting. In essence, this means we only transmit an empty secure setting if a previously configured value was cleared.
* Fix linting
* refactor omitEmptyUnlessExisting
* fixup
---------
Co-authored-by: Gilles De Mey <gilles.de.mey@gmail.com>
* SQLStore: Fix Postgres dialect treating "false" migrator default as true
Previously, when creating a migration you could choose a default value for a new
boolean column that looked correct but would be interpreted incorrectly by the
Postgres dialect. For example, values such as "false" or "FALSE" would be treated
as true by the Postgres dialect.
This refactors how migration dialects determine the Default column value for boolean
type columns. Each dialect now uses the same base code to parse the Default literal
and panics if an unknown value is encountered.
So, now AddColumnMigration and AddTableMigration will ensure that across dialects:
- The exact same Default literals will be allowed.
- The literals are converted to equivalent defaults in their DDL.
- An error will be thrown if an invalid literal is provided.
* Alerting: Repurpose rule testing endpoint to return potential alerts
This feature replaces the existing no-longer in-use grafana ruler testing API endpoint /api/v1/rule/test/grafana. The new endpoint returns a list of potential alerts created by the given alert rule, including built-in + interpolated labels and annotations.
The key priority of this endpoint is that it is intended to be as true as possible to what would be generated by the ruler except that the resulting alerts are not filtered to only Resolved / Firing and ready to be sent.
This means that the endpoint will, among other things:
- Attach static annotations and labels from the rule configuration to the alert instances.
- Attach dynamic annotations from the datasource to the alert instances.
- Attach built-in labels and annotations created by the Grafana Ruler (such as alertname and grafana_folder) to the alert instances.
- Interpolate templated annotations / labels and accept allowed template functions.
* Alerting: Fix unique violation when updating rule group with title chains/cycles
The uniqueness constraint for titles within an org+folder is enforced on every update within a transaction instead of on commit (deferred constraint). This means that there could be a set of updates that will throw a unique constraint violation in an intermediate step even though the final state is valid. For example, a chain of updates RuleA -> RuleB -> RuleC could fail if not executed in the correct order, or a swap of titles RuleA <-> RuleB cannot be executed in any order without violating the constraint.
The exact solution to this is complex and requires determining directed paths and cycles in the update graph, adding in temporary updates to break cycles, and then executing the updates in reverse topological order (see first commit in PR if curious).
This is not implemented here.
Instead, we choose a simpler solution that works in all cases but might perform more updates than necessary. This simpler solution makes a determination of whether an intermediate collision could occur and if so, adds a temporary title on all updated rules to break any cycles and remove the need for specific ordering.
In addition, we make sure diffs are executed in the following order: DELETES, UPDATES, INSERTS.
* Alerting: Fix provisioned templates being ignored by alertmanager
Template provisioning sets the template in cfg.TemplateFiles while a recent change
made it so that alertmanager reads cfg.AlertmanagerConfig.Templates instead.
This change fixes the issue on both ends, by having provisioning set boths fields and
reverts the change on the alertmanager side so that it uses cfg.TemplateFiles.
Alerting: Add totalsFiltered to RuleResponse to facilitate hidden by filters count
Currently, when both a limit_alerts and a matcher/state filter is applied, there is not enough information to determine how many alert instances were hidden by the filters. Only enough to determine the total hidden by the limit and filter combined.
This change adds a separate totalsFiltered field alongside the AlertRule totals that will contain the count of instances after filters but before limits.
* Alerting: Remove and revert flag alertingBigTransactions
This is a partial revert of #56575 and a removal of the `alertingBigTransactions` flag.
Real-word use has seen no clear performance incentive to maintain this flag. Lowered db connection count
came at the cost of significant increase in CPU usage and query latency.
* Fix lint backend
* Removed last bits of alertingBigTransactions
---------
Co-authored-by: Armand Grillet <2117580+armandgrillet@users.noreply.github.com>
* Alerting: Add endpoint to revert to a previous alertmanager configuration
This endpoint is meant to be used in conjunction with /api/alertmanager/grafana/config/history to
revert to a previously applied alertmanager configuration. This is done by ID instead of raw config
string in order to avoid secure field complications.
* Alerting: Respect "For" Duration for NoData alerts
This change modifies `resultNoData` to be more inline with the logic of the other state handlers.
The main effects of this are:
1) NoData states with NoDataState config set to Alerting will respect "For" duration.
2) Prevents zero value in StartsAt and EndsAt for alerts that have only even been in normal state. This includes state transitions from NoDataState=OK and ExecErrState=OK.
3) Better state transition logging.
* Alerting: Fix template validation in provisioning api
Fix issue where provisioning API accepts a malformed template having extra
text outside of definition block and template name matching definition name.
This adds provisioning endpoints for downloading alert rules and alert rule groups in a
format that is compatible with file provisioning. Each endpoint supports both json and
yaml response types via Accept header as well as a query parameter
download=true/false that will set Content-Disposition to recommend initiating a download
or inline display.
This also makes some package changes to keep structs with potential to drift closer
together. Eventually, other alerting file structs should also move into this new file
package, but the rest require some refactoring that is out of scope for this PR.
* Alerting: Improve legacy migration to include send reminder & frequency
Legacy channel frequency is migrated to the channel's migrated route's
repeat interval if send reminder is true. If send reminder is false, we
pseudo-disable the repeat interval by setting it to a large value (1y).
If there were no default channels, the root notification policy is still
created with the default 4h repeat interval.
* Alerting: Prevent short uid collision in legacy migration when db is case-insensitive
Two factors come into play that cause sporadic uid conflicts during legacy alert migration:
- MySQL and MySQL-compatible backends use case-insensitive collation.
- Our short uid generator is not a uniform RNG and generates uids in such a way that generations in quick succession have a higher probability of creating similar uids.
Normally we would be guaranteed unique short uid generation, however if the source alphabet contains
duplicate characters (for example, if we use case-insensitive comparison) this guarantee is void.
Generating even ~1000 uids in quick succession is nearly guaranteed to create a case-insensitive
duplicate.
* Alerting: Improve notification policies created during migration
Previously, migrated legacy alerts were connected to notification policies through
a `rule_uid` label in a 1:1 fashion. While this correctly mimicked pre-migration routing,
it didn't create a notification policy structure that is easy to view/modify. In addition,
having one policy per migrated alert is, in some ways, counter to the recommended approach of
Unified Alerting.
This change replaces `rule_uid`-based migrated notification policies with a private
label called `__contacts__`. This label stores a list of double quoted strings containing the names of
all contact points an AlertRule should route to (based on legacy notification channels). Finally,
one notification policy is created per contact point with each matching AlertRules via regex on this
`__contacts__` label.
The result is a simpler, clearer, and easier to modify notification policy structure, with the
added benefit that you can see which contact points an AlertRule is being routed to from the
AlertRule creation page.
* Alerting: Sanitize invalid label/annotation names for external alertmanagers
Grafana's built-in Alertmanager supports both Unicode label keys and values; however, if using an external
Prometheus Alertmanager label keys must be compatible with their data model.
This means label keys must only contain ASCII letters, numbers, as well as underscores and match the regex
`[a-zA-Z_][a-zA-Z0-9_]*`.
Any invalid characters will now be removed or replaced by the Grafana alerting engine before being sent to
the external Alertmanager according to the following rules:
- `Whitespace` will be removed.
- `ASCII characters` will be replaced with `_`.
- `All other characters` will be replaced with their lower-case hex representation.
* Prefix hex replacements with `0x`
* Refactor for clarity
* Apply suggestions from code review
Co-authored-by: brendamuir <100768211+brendamuir@users.noreply.github.com>
Co-authored-by: brendamuir <100768211+brendamuir@users.noreply.github.com>
* Alerting: Add config disabled_labels to disable reserved labels
[unified_alerting.reserved_labels]
disabled_labels
* Replace IsGrafanaFolderDisabled with more generic IsReservedLabelDisabled
* Simplify SchedulerCfg by including UnifiedAlertingSettings
* Alerting: Update default route groupBy to [grafana_folder, alertname]
Default group by for new routes and migrations is now [grafana_folder, alertname]
* Alerting: Add first Grafana reserved label g_label
g_label holds the title of the folder container the alert. The intention of this label
is to use it as part of the new default notification policy groupBy.
* Add nil check on updateRule labels map
* Disable gocyclo lint on schedule.ruleRoutine
will remove later in a separate refactoring PR to reduce complexity.
* Address doc suggestions
* Update g_folder for rules in folder when folder title changes
* Remove global bus in FolderService
* Modify tests to fit new common g_folder label
* Add changelog entry
* Fix merge conflicts
* Switch GrafanaReservedLabelPrefix from `g_` to `grafana_`
If SQLite is used and the database is locked temporarily (ex. heavy write-load) during periodic
AM config sync, it was possible for your AM config to be overwritten with the default one.
This fixes that by patching a bug in xorm v0.8.2 which was causing SQLITE_BUSY errors to be ignored
in certain cases.
* Alerting: Create fewer contact points on migration
Previously a new contact point was created for every unique combination
of channels attached to any legacy alert. This was very hard to maintain,
requiring modifications in every generated contact point.
This change deduplicates the generated contact points to a more
reasonable state. There should now only be one contact point per legacy
channel, and we attached multiple contact points to a route by nesting
them. The sole exception to this is if there were multiple default
legacy channels, in which case we create a redundant contact point
containing all of them used only in the root policy. This allows for a
much simpler notification policy structure.
Co-authored-by: gotjosh <josue.abreu@gmail.com>
* Alerting: Add integration test for AddDashAlertMigration
* Add more targeted test cases
* Apply suggestions from code review
Co-authored-by: gotjosh <josue.abreu@gmail.com>
* Reorganize file and improve comments
* Replace custom sort+trim with go-cmp
* Add test for AddDashAlertMigration
* Rename test cases to standard format
* Apply suggestions from code review
Co-authored-by: gotjosh <josue.abreu@gmail.com>
* Remove test-only snapshots of PostableUserConfig et al.
* Organize imports
* Fix linting
Co-authored-by: gotjosh <josue.abreu@gmail.com>