* Deletes the copy of the code in ThirdPary folder
* Replace code with opm-flowdiagnostics-applications as submodule
* Refactors ECL data handling for flow diagnostics
Updates flow diagnostics to utilize ECL init data consistently.
This change streamlines the passing and usage of initialization
data within the flow diagnostics routines, enhancing code
clarity and maintainability. Removes redundant passing of grid
data, simplifying function signatures.
* Add special handling for TieIn ICVs, and keep default outlet segment for other completion types(fishbones, fractures, ...)
* Update unit test related to change of tie-in logic
Adds a null check for the eclResDef pointer before accessing its members.
This prevents a potential crash if eclResDef is null.
Additionally, the unnecessary assertions are removed.
Improves result info handling by ensuring the result
definition is valid before accessing it, preventing
potential crashes.
Uses `if (auto)` to check for null result definitions,
and displays a user-friendly message when no result
definition is available.
When creating delta for an ongoing simulation, the length of time and value vectors can differ. Resize these vectors to make sure they have the same length to avoid crash.
* Add view job log command.
* Add stop job command.
* Do not block ui while job is running.
* Show progress while job is running
* Make sure user gets notified of running jobs when exiting ResInsight or closing current project.
Introduces common readout settings for summary multi plots, allowing users to apply a single readout configuration across multiple plots instead of configuring each individually.
This is a follow-up to the fix where the assert was removed in 9a71abd8af.
This fix will make sure that the search tree always is created when findIntersectingCells() is called.
When working with a summary ensemble in a Debug build on Windows, a crash happened in RiuQwtPlotWidget::resetPlotCurveHighlighting(). When iterating over list of plot items, one pointer to item pointed to 0xddddddd, a clear indication that the underlying list had been updated during the loop and the iterator invalidated.
The change ensures that modifications to the item list during iteration do not cause unexpected behavior, particularly in scenarios involving grid lines and curve highlighting.
This is achieved by making a copy of the item list before iteration when modifications may occur. For cases where no add/remove will be performed during the iteration, a comment is added to clarify that it is safe to access the reference to the list.
Positions the ICD segment at the end of the fishbone section to ensure that lateral MDs are larger than the ICD segment MDs.
This is required by the simulator and ensures correct flow modeling from laterals into the ICD segment.