Prepare Restart File Support for Valves and ICDs
This commit identifies certain items in restart vectors ISEG and RSEG that pertain to valves (keyword WSEGVALV) and spiral ICDs (keyword WSEGSICD). In particular, we identify segment type flag and a couple of relevant values for this flag. Also, relevant parameters that describe the geometry and pressure drops of these devices.
This commit is contained in:
@@ -30,7 +30,20 @@ namespace Opm { namespace RestartIO { namespace Helpers { namespace VectorItems
|
||||
OutSeg = 1, // Outlet segment (one-based)
|
||||
InSegCurBranch = 2, // Inflow segment current branch (one-based)
|
||||
BranchNo = 3, // Branch number (one-based)
|
||||
|
||||
SegmentType = 11,
|
||||
|
||||
ICDScalingMode = 18,
|
||||
ICDOpenShutFlag = 19,
|
||||
};
|
||||
|
||||
namespace Value {
|
||||
enum SegmentType : int {
|
||||
AICD = -8,
|
||||
SICD = -7,
|
||||
Valve = -5,
|
||||
};
|
||||
} // Value
|
||||
} // ISeg
|
||||
|
||||
namespace RSeg {
|
||||
@@ -50,6 +63,26 @@ namespace Opm { namespace RestartIO { namespace Helpers { namespace VectorItems
|
||||
Pressure = 11, // Segment pressure
|
||||
|
||||
item40 = 39, // Unknown
|
||||
|
||||
ValveLength = 40, // Length of valve
|
||||
ValveArea = 41, // Cross-sectional area of valve
|
||||
ValveFlowCoeff = 42, // Valve's dimensionless flow coefficient
|
||||
ValveMaxArea = 43, // Maximal cross-sectional valve area
|
||||
|
||||
DeviceBaseStrength = 86,
|
||||
|
||||
CalibrFluidDensity = 88,
|
||||
CalibrFluidViscosity = 89,
|
||||
|
||||
CriticalWaterFraction = 90,
|
||||
TransitionRegWidth = 91,
|
||||
MaxEmulsionRatio = 92,
|
||||
MaxValidFlowRate = 97,
|
||||
|
||||
ICDLength = 102,
|
||||
|
||||
ValveAreaFraction = 103,
|
||||
|
||||
item106 = 105, // Unknown
|
||||
item107 = 106, // Unknown
|
||||
item108 = 107, // Unknown
|
||||
|
||||
Reference in New Issue