Bård Skaflestad 1311afb261 PVTO: Add Means of Identifying Non-Monotonic Saturated FVFs
This commit introduces a way of diagnosing an uncommon but possible
issue in the PVTO table.  If the formation volume factor (BO) in the
saturated table (record 1 of each subtable) does not increase
monotonically as a function of the dissolved gas/oil ratio (RS),
then there is a risk that the simulation run will have convergence
problems.

We add a special purpose member function

    PvtoTable::nonMonotonicSaturatedFVF

which checks for this condition and returns a vector records for
which the condition is true.  The new member function

    TableManager::checkPVTOMonotonicity

then collates these records into a formatted string which is printed
to the console and the .PRT file.

Example Diagnostic Output:

    Warning: Non-Monotonic Oil Formation Volume Factor Detected
      * PVTO [PVTNUM = 1]
        Record  9: FVF 1.23 at RS 123 is not greater than FVF 2.34 at RS 120
        Record 10: FVF 1.22 at RS 125 is not greater than FVF 1.23 at RS 123
        Record 11: FVF 1.21 at RS 125 is not greater than FVF 1.22 at RS 125