Fix bug in use of perforation data, and check that well contstruction calls succeed.

This commit is contained in:
Atgeirr Flø Rasmussen 2012-05-03 12:49:37 +02:00
parent 373a4f2689
commit 361593fa45

View File

@ -367,14 +367,17 @@ namespace Opm
std::vector<int> perf_cells(w_num_perf);
std::vector<double> perf_prodind(w_num_perf);
for (int perf = 0; perf < w_num_perf; ++perf) {
perf_cells[0] = wellperf_data[w][perf].cell;
perf_prodind[0] = wellperf_data[w][perf].well_index;
perf_cells[perf] = wellperf_data[w][perf].cell;
perf_prodind[perf] = wellperf_data[w][perf].well_index;
}
const double* comp_frac = NULL;
// We initialize all wells with a null component fraction,
// and must (for injection wells) overwrite it later.
add_well(well_data[w].type, well_data[w].reference_bhp_depth, w_num_perf,
comp_frac, &perf_cells[0], &perf_prodind[0], w_);
int ok = add_well(well_data[w].type, well_data[w].reference_bhp_depth, w_num_perf,
comp_frac, &perf_cells[0], &perf_prodind[0], w_);
if (!ok) {
THROW("Failed adding well " << well_names[w] << " to Wells data structure.");
}
}
// Get WCONINJE data, add injection controls to wells.
@ -400,27 +403,31 @@ namespace Opm
}
// Add all controls that are present in well.
int ok = 1;
int control_pos[5] = { -1, -1, -1, -1, -1 };
if (wci_line.surface_flow_max_rate_ > 0.0) {
if (ok && wci_line.surface_flow_max_rate_ > 0.0) {
control_pos[InjectionControl::RATE] = w_->ctrls[wix]->num;
const double distr[3] = { 1.0, 1.0, 1.0 };
append_well_controls(SURFACE_RATE, wci_line.surface_flow_max_rate_,
distr, wix, w_);
ok = append_well_controls(SURFACE_RATE, wci_line.surface_flow_max_rate_,
distr, wix, w_);
}
if (wci_line.reservoir_flow_max_rate_ > 0.0) {
if (ok && wci_line.reservoir_flow_max_rate_ > 0.0) {
control_pos[InjectionControl::RESV] = w_->ctrls[wix]->num;
const double distr[3] = { 1.0, 1.0, 1.0 };
append_well_controls(RESERVOIR_RATE, wci_line.reservoir_flow_max_rate_,
distr, wix, w_);
ok = append_well_controls(RESERVOIR_RATE, wci_line.reservoir_flow_max_rate_,
distr, wix, w_);
}
if (wci_line.BHP_limit_ > 0.0) {
if (ok && wci_line.BHP_limit_ > 0.0) {
control_pos[InjectionControl::BHP] = w_->ctrls[wix]->num;
append_well_controls(BHP, wci_line.BHP_limit_,
NULL, wix, w_);
ok = append_well_controls(BHP, wci_line.BHP_limit_,
NULL, wix, w_);
}
if (wci_line.THP_limit_ > 0.0) {
if (ok && wci_line.THP_limit_ > 0.0) {
THROW("We cannot handle THP limit for well " << well_names[wix]);
}
if (!ok) {
THROW("Failure occured appending controls for well " << well_names[wix]);
}
InjectionControl::Mode mode = InjectionControl::mode(wci_line.control_mode_);
const int cpos = control_pos[mode];
if (cpos == -1 && mode != InjectionControl::GRUP) {
@ -477,37 +484,38 @@ namespace Opm
}
// Add all controls that are present in well.
int control_pos[9] = { -1, -1, -1, -1, -1, -1, -1, -1, -1 };
if (wcp_line.oil_max_rate_ > 0.0) {
int ok = 1;
if (ok && wcp_line.oil_max_rate_ > 0.0) {
if (!pu.phase_used[BlackoilPhases::Liquid]) {
THROW("Oil phase not active and ORAT control specified.");
}
control_pos[ProductionControl::ORAT] = w_->ctrls[wix]->num;
double distr[3] = { 0.0, 0.0, 0.0 };
distr[pu.phase_pos[BlackoilPhases::Liquid]] = 1.0;
append_well_controls(SURFACE_RATE, wcp_line.oil_max_rate_,
distr, wix, w_);
ok = append_well_controls(SURFACE_RATE, wcp_line.oil_max_rate_,
distr, wix, w_);
}
if (wcp_line.water_max_rate_ > 0.0) {
if (ok && wcp_line.water_max_rate_ > 0.0) {
if (!pu.phase_used[BlackoilPhases::Aqua]) {
THROW("Water phase not active and WRAT control specified.");
}
control_pos[ProductionControl::WRAT] = w_->ctrls[wix]->num;
double distr[3] = { 0.0, 0.0, 0.0 };
distr[pu.phase_pos[BlackoilPhases::Aqua]] = 1.0;
append_well_controls(SURFACE_RATE, wcp_line.water_max_rate_,
distr, wix, w_);
ok = append_well_controls(SURFACE_RATE, wcp_line.water_max_rate_,
distr, wix, w_);
}
if (wcp_line.gas_max_rate_ > 0.0) {
if (ok && wcp_line.gas_max_rate_ > 0.0) {
if (!pu.phase_used[BlackoilPhases::Vapour]) {
THROW("Gas phase not active and GRAT control specified.");
}
control_pos[ProductionControl::GRAT] = w_->ctrls[wix]->num;
double distr[3] = { 0.0, 0.0, 0.0 };
distr[pu.phase_pos[BlackoilPhases::Vapour]] = 1.0;
append_well_controls(SURFACE_RATE, wcp_line.gas_max_rate_,
distr, wix, w_);
ok = append_well_controls(SURFACE_RATE, wcp_line.gas_max_rate_,
distr, wix, w_);
}
if (wcp_line.liquid_max_rate_ > 0.0) {
if (ok && wcp_line.liquid_max_rate_ > 0.0) {
if (!pu.phase_used[BlackoilPhases::Aqua]) {
THROW("Water phase not active and LRAT control specified.");
}
@ -518,23 +526,26 @@ namespace Opm
double distr[3] = { 0.0, 0.0, 0.0 };
distr[pu.phase_pos[BlackoilPhases::Aqua]] = 1.0;
distr[pu.phase_pos[BlackoilPhases::Liquid]] = 1.0;
append_well_controls(SURFACE_RATE, wcp_line.liquid_max_rate_,
distr, wix, w_);
ok = append_well_controls(SURFACE_RATE, wcp_line.liquid_max_rate_,
distr, wix, w_);
}
if (wcp_line.reservoir_flow_max_rate_ > 0.0) {
if (ok && wcp_line.reservoir_flow_max_rate_ > 0.0) {
control_pos[ProductionControl::RESV] = w_->ctrls[wix]->num;
double distr[3] = { 1.0, 1.0, 1.0 };
append_well_controls(RESERVOIR_RATE, wcp_line.reservoir_flow_max_rate_,
ok = append_well_controls(RESERVOIR_RATE, wcp_line.reservoir_flow_max_rate_,
distr, wix, w_);
}
if (wcp_line.BHP_limit_ > 0.0) {
if (ok && wcp_line.BHP_limit_ > 0.0) {
control_pos[ProductionControl::BHP] = w_->ctrls[wix]->num;
append_well_controls(BHP, wcp_line.BHP_limit_,
ok = append_well_controls(BHP, wcp_line.BHP_limit_,
NULL, wix, w_);
}
if (wcp_line.THP_limit_ > 0.0) {
if (ok && wcp_line.THP_limit_ > 0.0) {
THROW("We cannot handle THP limit for well " << well_names[wix]);
}
if (!ok) {
THROW("Failure occured appending controls for well " << well_names[wix]);
}
ProductionControl::Mode mode = ProductionControl::mode(wcp_line.control_mode_);
const int cpos = control_pos[mode];