change control eq tol for standard wells

This commit is contained in:
Tor Harald Sandve 2019-10-18 16:03:21 +02:00
parent 9bd44dc79a
commit cd0bf8045d

View File

@ -3462,7 +3462,7 @@ namespace Opm
case Well2::InjectorCMode::RATE:
case Well2::InjectorCMode::RESV:
ctrltype = CR::WellFailure::Type::ControlRate;
control_tolerance = 1.e-6; //
control_tolerance = 1.e-4; //
break;
case Well2::InjectorCMode::GRUP:
ctrltype = CR::WellFailure::Type::ControlRate;
@ -3491,7 +3491,7 @@ namespace Opm
case Well2::ProducerCMode::RESV:
case Well2::ProducerCMode::CRAT:
ctrltype = CR::WellFailure::Type::ControlRate;
control_tolerance = 1.e-6; // smaller tolerance for rate control
control_tolerance = 1.e-4; // smaller tolerance for rate control
break;
case Well2::ProducerCMode::GRUP:
ctrltype = CR::WellFailure::Type::ControlRate;