@ -37,44 +37,16 @@
namespace Opm {
namespace detail {
static double threshold = 1e-12;
/**
* Returns zero if input value is NaN of INF
* Returns zero if input value is negative
*/
inline double zeroIfNanInf(const double& value, const std::string& rate, const VFPProdTable& table) {
const bool nan_or_inf = std::isnan(value) || std::isinf(value);
if (nan_or_inf) {
std::string msg = "Problem with VFPPROD keyword table " + std::to_string(table.getTableNum()) + "\n" +
"In " + table.location().filename + " line " + std::to_string(table.location().lineno) + "\n"
"Nan or inf encountered while calculating " + rate + " - using zero";
OpmLog::warning("NAN_OR_INF_VFP", msg);
}
return nan_or_inf ? 0.0 : value;
template <typename T>
static T chopNegativeValues(const T& value) {
return Opm::max(0.0, value);
}
/**
* Returns zero if input value is NaN or INF
*/
template <class EvalWell>
inline EvalWell zeroIfNanInf(const EvalWell& value, const std::string& rate, const VFPProdTable& table) {
const bool nan_or_inf = std::isnan(value.value()) || std::isinf(value.value());
if (nan_or_inf) {
std::string msg = "Problem with VFPPROD keyword table " + std::to_string(table.getTableNum()) + "\n" +
"In " + table.location().filename + " line " + std::to_string(table.location().lineno) + "\n"
"Nan or inf encountered while calculating " + rate + " - using zero";
OpmLog::warning("NAN_OR_INF_VFP_EVAL", msg);
}
using Toolbox = MathToolbox<EvalWell>;
return nan_or_inf ? Toolbox::createConstantZero(value) : value;
}
/**
* Computes the flo parameter according to the flo_type_
* for production tables
@ -137,18 +109,16 @@ template <typename T>
static T getWFR(const VFPProdTable& table, const T& aqua, const T& liquid, const T& vapour) {
auto type = table.getWFRType();
switch(type) {
case VFPProdTable::WFR_TYPE::WFR_WOR:
case VFPProdTable::WFR_TYPE::WFR_WOR: {
//Water-oil ratio = water / oil
return zeroIfNanInf(aqua/liquid, "WOR", table);
return chopNegativeValues(-aqua) / Opm::max(threshold, chopNegativeValues(-liquid));
}
case VFPProdTable::WFR_TYPE::WFR_WCT:
//Water cut = water / (water + oil)
return zeroIfNanInf(aqua / (aqua + liquid), "WCT", table);
return chopNegativeValues(-aqua) / Opm::max(threshold, chopNegativeValues(-aqua - liquid));
case VFPProdTable::WFR_TYPE::WFR_WGR:
//Water-gas ratio = water / gas
return zeroIfNanInf(aqua / vapour, "WGR", table);
return chopNegativeValues(-aqua) / Opm::max(threshold, chopNegativeValues(-vapour));
default:
throw std::logic_error("Invalid WFR_TYPE");
}
@ -169,13 +139,13 @@ static T getGFR(const VFPProdTable& table, const T& aqua, const T& liquid, const
switch(type) {
case VFPProdTable::GFR_TYPE::GFR_GOR:
// Gas-oil ratio = gas / oil
return zeroIfNanInf(vapour / liquid, "GOR", table);
return chopNegativeValues(-vapour) / Opm::max(threshold, chopNegativeValues(-liquid));
case VFPProdTable::GFR_TYPE::GFR_GLR:
// Gas-liquid ratio = gas / (oil + water)
return zeroIfNanInf(vapour / (liquid + aqua), "GLR", table);
return chopNegativeValues(-vapour) / Opm::max(threshold, chopNegativeValues(-liquid - aqua));
case VFPProdTable::GFR_TYPE::GFR_OGR:
// Oil-gas ratio = oil / gas
return zeroIfNanInf(liquid / vapour, "OGR", table);
return chopNegativeValues(-liquid) / Opm::max(threshold, chopNegativeValues(-vapour));
default:
throw std::logic_error("Invalid GFR_TYPE");
}