Enable Restart Tests for Constant Flux Aquifers

Uses the example models AQUFLUX-01 and AQUFLUX-02 from OPM-Tests.
Both sequential and parallel modes activated for both models.
This commit is contained in:
Bård Skaflestad 2023-05-25 18:41:56 +02:00
parent 7a77f28b71
commit f156bc9b7d
5 changed files with 53 additions and 1 deletions

View File

@ -44,6 +44,24 @@ add_test_compare_parallel_restarted_simulation(CASENAME numerical_aquifer_3d_1aq
DIR aquifer-num
TEST_ARGS --enable-tuning=true --tolerance-cnv=0.00003 --time-step-control=pid --linear-solver=cpr_trueimpes)
add_test_compare_parallel_restarted_simulation(CASENAME aquflux_01
FILENAME AQUFLUX-01
SIMULATOR flow
ABS_TOL ${abs_tol_restart}
REL_TOL 5.0e-2
RESTART_STEP 3
DIR aquifers
TEST_ARGS --solver-max-time-step-in-days=1)
add_test_compare_parallel_restarted_simulation(CASENAME aquflux_02
FILENAME AQUFLUX-02
SIMULATOR flow
ABS_TOL ${abs_tol_restart}
REL_TOL 5.0e-2
RESTART_STEP 50
DIR aquifers
TEST_ARGS --solver-max-time-step-in-days=1)
# Serialized restart tests
if(HDF5_FOUND)
opm_set_test_driver(${PROJECT_SOURCE_DIR}/tests/run-serialization-regressionTest.sh "")

View File

@ -141,6 +141,14 @@ add_test_compare_parallel_simulation(CASENAME aquflux_01
DIR aquifers
TEST_ARGS --enable-tuning=true)
add_test_compare_parallel_simulation(CASENAME aquflux_02
FILENAME AQUFLUX-02
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${coarse_rel_tol_parallel}
DIR aquifers
TEST_ARGS --enable-tuning=true)
add_test_compare_parallel_simulation(CASENAME network_balance_01
FILENAME NETWORK-01
SIMULATOR flow

View File

@ -199,7 +199,14 @@ add_test_compareECLFiles(CASENAME aquflux_01
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${rel_tol}
DIR aquifers)
DIR aquifers --solver-max-time-step-in-days=1)
add_test_compareECLFiles(CASENAME aquflux_02
FILENAME AQUFLUX-02
SIMULATOR flow
ABS_TOL ${abs_tol}
REL_TOL ${rel_tol}
DIR aquifers --solver-max-time-step-in-days=1)
add_test_compareECLFiles(CASENAME spe3
FILENAME SPE3CASE1

View File

@ -56,6 +56,24 @@ add_test_compare_restarted_simulation(CASENAME numerical_aquifer_3d_2aqu
DIR aquifer-num
TEST_ARGS --sched-restart=true --enable-tuning=true)
add_test_compare_restarted_simulation(CASENAME aquflux_01
FILENAME AQUFLUX-01
SIMULATOR flow
ABS_TOL ${abs_tol_restart}
REL_TOL 3.0e-3
RESTART_STEP 3
DIR aquifers
TEST_ARGS --enable-tuning=true)
add_test_compare_restarted_simulation(CASENAME aquflux_02
FILENAME AQUFLUX-02
SIMULATOR flow
ABS_TOL ${abs_tol_restart}
REL_TOL ${rel_tol_restart}
RESTART_STEP 50
DIR aquifers
TEST_ARGS --enable-tuning=true)
# The dynamic MSW data is not written to /read from the restart file
# We therefore accept significant deviation in the results.
# Note also that we use --sched-restart=true since some necessary

View File

@ -85,6 +85,7 @@ tests[fetkovich_2d]="flow aquifer-fetkovich 2D_FETKOVICHAQUIFER"
tests[numerical_aquifer_3d_1aqu]="flow aquifer-num 3D_1AQU_3CELLS"
tests[numerical_aquifer_3d_2aqu]="flow aquifer-num 3D_2AQU_NUM"
tests[aquflux_01]="flow aquifers AQUFLUX-01"
tests[aquflux_02]="flow aquifers AQUFLUX-02"
tests[msw_2d_h]="flow msw_2d_h 2D_H__"
tests[msw_3d_hfa]="flow msw_3d_hfa 3D_MSW"
tests[polymer_oilwater]="flow polymer_oilwater 2D_OILWATER_POLYMER"